Advertisement

AR BLUE CLEAN
6630 - 6640 - 6650 - 6670
Read carefully the present use and maintenance manual in every part before
proceeding to use. The following machine has been examined according to the
Directive Machines 2006/42, 2004/108, 2006/95 and following changes and
integrations.
USE AND MAINTENANCE HANDBOOK
https://www.kipogeorgiki.gr/
ΦΥΤΑ - ΜΗΧΑΝΗΜΑΤΑ - ΕΡΓΑΛΕΙΑ
18ο Χλμ. Εθνικής Οδού ΑΘΗΝΩΝ-ΚΟΡΙΝΘΟΥ
E-mail:
Annovi Reverberi S.p.A
SERVICE Dept.
Via Aldo Moro, 40/42
41030 Bomporto (MO) – Italy
supporth@annovireverberi.it
https://www.kipogeorgiki.gr/
6630 - 6640 - 6650 - 6670
Τηλέφωνο: 2105573739
info@kipogeorgiki.gr
USE AND
MAINTENANCE
HANDBOOK
Code XXXXX - XX
page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6630 and is the answer not in the manual?

Questions and answers

Summary of Contents for AR Blue Clean 6630

  • Page 1 AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 ΦΥΤΑ - ΜΗΧΑΝΗΜΑΤΑ - ΕΡΓΑΛΕΙΑ 18ο Χλμ. Εθνικής Οδού ΑΘΗΝΩΝ-ΚΟΡΙΝΘΟΥ Τηλέφωνο: 2105573739 E-mail: info@kipogeorgiki.gr 6630 - 6640 - 6650 - 6670 Read carefully the present use and maintenance manual in every part before proceeding to use.
  • Page 2: Table Of Contents

    Congratulation for your choice on the purchase of your new cleaner; it means that you have keep technical knowledge and good taste for the nice design. Technological innovation, high performances and strenght are the main features of the machine 6630 / 6640 / 6650 / 6670.
  • Page 3: Machine Identification Plate

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 The machine has been designed to clean or wash, with hot or cold water, objects or surfaces which can stand the mechanical treatment of the water jet under high pressure and by the action of the chemicals products (detergents).
  • Page 4: Technical Features And Dimensions

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 TECHNICAL FEATURES AND DIMENSIONS MODEL 6630 6640 6650 6670 Pressure P.S.I. 2200 1900 2200 2500 2,32 (OUTPUT) Power (INPUT) 2800 1450 1450 1450 230-50Hz 230-50Hz 400-50Hz 400-50Hz Voltage V/Hz...
  • Page 5: Main Parts

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 MAIN PARTS 1 = THERMAL LANCE 14 = FUEL TANK CAP 2 = HIGH PRESSURE HOSE 15 = CHIMNEY UNLOADED SMOKES 3 = WATER OUTLET 16 = BOILER 4 = WATER INLET...
  • Page 6: Jobs And Safety Rules

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 JOBS AND SAFETY RULES Please be sure that the machine is always fed with water. Running the unit dry, causes serious damages to the sealing systems. Never attempt to move the unit by dragging it by the power cord of the high pressure machine.
  • Page 7: Machine Installation

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 MACHINE INSTALLATION The machine you are about to use will give you the best performances if you install itself following our instructions. Before setting the machine at work, make sure that the machine lies perfectly on a horizontal surface.
  • Page 8: Machine Running

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 MACHINE RUNNING After having installed the machine, it can be started; open the water faucet H, press the start button I and pull on the gun lever L for a few seconds, in a way to discharge the air contained in the hose.
  • Page 9: Electric Wiring Diagram

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 ELECTRIC WIRING DIAGRAM SINGLE PHASE DIAGRAM FOR AR 6630/6640 WITH 4 MODE PRINT BOARD ALB012 GENERAL ON-OFF SWITCH PRESSURE SWITCH 15 BAR THERMAL PROTECTOR PRESSURE SWITCH 40 BAR FUSE...
  • Page 10 AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 TRHEE-PHASES DIAGRAM FOR AR 6650/6670 WITH 4 MODE PRINT BOARD ALB012 GENERAL ON-OFF SWITCH PRESSURE SWITCH 15 BAR THERMAL PROTECTOR PRESSURE SWITCH 40 BAR FUSE THERMOSTAT SWITCH BURNER TRASFORMER...
  • Page 11: Labels

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 LABELS 1 Electrocution controls box 2 Danger! Gases at high temperature - outlet 3 Outlet 4 Water supply 5 Earth connection 6 Detergent intake 7 Caution! Don’t direct the high pressure jet towards people, animals, wiring installations, etc…….
  • Page 12: Maintenance

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 MAINTENANCE IMPORTANT!  Maintenance and repairs must be executed by qualified individuals.  All maintenance operations must be carried out with the machine placed on an even plane and disconnected from the main power and from the water supply.
  • Page 13: Cooling Coil Internal Cleaning

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 Every month or after 100 hours of work Clean the combustion head and check the electrodes. Remove the cover, unscrew the three screws pos. A, extract the combustion head group pos. B. Clean with an air jet the head and check the glow plug pos.
  • Page 14: Machine Demolition

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 MACHINE DEMOLITION If you want to junk your machine, please comply to the laws in force in your Country. The machine is manufactured with parts containing recyclable metals and plastics. The oil found inside the pump is highly dangerous and pollutant and must not be wasted in the environment or poured into civic drains.
  • Page 15: Declaration Of Conformity

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Declares taking full responsability that the product is in accordance with the following regulations and relative documents EN 60335-1 - EN 60335-2-79; EN 55014-1; EN 55014-2;...
  • Page 16: Supporth@Annovireverberi.it

    AR BLUE CLEAN 6630 - 6640 - 6650 - 6670 VIA ALDO MORO 41030 BOMPORTO (MO) ITALY supporth@annovireverberi.it USE AND MAINTENANCE HANDBOOK page 16 https://www.kipogeorgiki.gr/...