Telect BCS 4R User Manual

Telect BCS 4R User Manual

Connectivity system
Table of Contents

Advertisement

Quick Links

BCS 4R DSX-3 Connectivity System
Models 010-8332-0410, 010-8332-0401, 010-8324-0410
and 010-8324-0401
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BCS 4R and is the answer not in the manual?

Questions and answers

Summary of Contents for Telect BCS 4R

  • Page 1 BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and 010-8324-0401 User Manual...
  • Page 2 1730 N Madson St., Liberty Lake, Washington Telect assumes no liability from the application or use of these products. Neither does Telect convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.
  • Page 3: Table Of Contents

    1.1 Introduction to Telect’s BCS 4R ..................1 1.1.1 BCS 4R Fully-Loaded Chassis ................3 1.1.2 BCS 4R DSX-3 Module (Models 010-8301-0401 & 010-8302-0401) ...... 4 1.1.3 BCS 4R Chassis (Model 010-0000-8301 and 010-0000-8302) ......5 1.1.4 Applications ......................6 1.1.5 Cutover / Acceptance Activities ................
  • Page 4 Figure 16 - Rear Cross-Connect Cables with Tracer Wire ............19 Figure 17 - Temporary Front Cross-Connect Using Patch Cables & DSX Cards ...... 20 Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page iv...
  • Page 5: Chapter 1: Bcs 4R Dsx-3

    Telect’s BCS 4R is a low-cost, high-density, space-saving total solution to DSX-3 network element connectivity. Telect’s 2 RU BCS 4R chassis accommodates up to 32 of Telect’s highly reliable, 6-port BCS 4R DSX-3 modules. Each low-cost DSX-3 module features BNC and Mini-WECO connectors for cross-connecting, patching, testing.
  • Page 6: Figure 2 - Rear View Of Fully Loaded Chassis

    BCS 4R BCS 4R Figure 2 - Rear View of Fully Loaded Chassis Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 1-2...
  • Page 7: Bcs 4R Fully-Loaded Chassis

    Figure 3 - Network Element Circuits 1.1.1 BCS 4R Fully-Loaded Chassis Telect now provides fully-loaded 19” and 23” DSX-3 panels. These products come pre-loaded with either 6-port or 4-port modules. See the following table for part numbers. Table 1 - Fully-loaded 19” and 23” DSX-3 panels...
  • Page 8: Bcs 4R Dsx-3 Module (Models 010-8301-0401 & 010-8302-0401)

    The front of the module contains a red tracer LED fed by power supplied from a GMT power shelf. A tracer wire is inserted through the rear of the BCS 4R Chassis; the tracer lamp is lit by grounding the tracer wire at the trace controller. Tracer lamps aid in diagnosing problems by visually mapping out assigned network element cross connections.
  • Page 9: Bcs 4R Chassis (Model 010-0000-8301 And 010-0000-8302)

    1.1.3 BCS 4R Chassis (Model 010-0000-8301 and 010-0000-8302) The 23-in. and 19-in. BCS 4R Chassis are shelves containing 32 and 24 positions, respectively, for BCS 4R DSX-3 modules. Each chassis includes a power backplane to feed -48Vdc, tracer-lamp power to the DSX-3 modules.
  • Page 10: Applications

    Periodic testing of facility parameters assures maintenance of adequate service levels. By terminating all digital office equipment at one central point — at the BCS 4R DSX-3 — overall testing can be performed from the central location. Periodic testing at DSX test jacks, connected directly to digital equipment inputs and outputs, identifies marginal equipment.
  • Page 11: Features / Capabilities / Capacities / Benefits

    • NEBS Certified and backed by Telect's DSX lifetime warranty 1.1.9 Compliance • NEBs Level 3 • • • Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 1-7...
  • Page 12: Dsx-3 Specifications

    -55°C to 85°C, non-operating -5°C to +55°C, operating Thermal Shock per MIL-STD-202, methods 107D Humidity 0% to 95%, noncondensing, operating and non-operating Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 1-8...
  • Page 13: Chapter 2: Installation

    Use this equipment in a RESTRICTED ACCESS LOCATION ONLY. 2.1.1 Location and Space The BCS 4R chassis mount in standard 19 in. or 23 in. WECO-spaced or EIA-spaced racks. Allow for four inches of vertical space per chassis. Figure 6 - Rack Telect, Inc.
  • Page 14: Computer Floor Issues

    2.1.2 Computer Floor Issues The weight of a fully populated BCS 4R bay may exceed 500 lbs. Each configuration will vary in weight depending on number and type of cards and cables used. Adding repeaters will increase weight. If bay weight exceeds the support capacity of your floor, computer floor supports may be required.
  • Page 15: Installation

    2. Install cable management rings on the rear rack flange using the hardware provided. 3. Repeat Steps 1 and 2 to install all BCS 4R chassis before installing power and I/O cables to any BCS 4R chassis in the rack.
  • Page 16: Figure 8 - Routing Power

    Figure 8 - Routing Power Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 2-12...
  • Page 17: Figure 9 - Grounding The Chassis

    6. Connect I/O cables to the rear of the chassis, as shown in the following illustration. In general, • For network I/O cables originating overhead, start with the lowest BCS 4R chassis in the rack and work up. • For network I/O cables originating from below, start with the highest chassis in the rack and work down.
  • Page 18: Figure 11 - Connections

    9. If applicable, connect tracer wire to the port above the tracer LED, as shown. 10. Use cable ties along the upper tie-down bar to restrain the X-connect cables. Figure 11 - Connections Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 2-14...
  • Page 19: Figure 12 - Rear Cross-Connect Cables With Tracer Wire

    Figure 12 - Rear Cross-Connect Cables with Tracer Wire Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 2-15...
  • Page 20 This page intentionally left blank. Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 2-16...
  • Page 21: Chapter 3: Electrical Operation

    Chapter 3: Electrical Operation 3.1 Power The BCS 4R equipment is passive with the exception of the repeater and Vector OTM card modules. The DSX chassis accept -48V office battery power to light the tracer lamps (TL) LED on the front of DSX and repeater cards and LEDs on the rear of the chassis.
  • Page 22: Tracer Lamps (Tl)

    1 (NE-1) to the IX (X-IN) for network element 2 (NE-2), AND connect the OX port for NE-2 to the IX port from NE-1. See the diagrams below. Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 3-18...
  • Page 23: Figure 15 - Schematic Drawing Of Cross-Connection

    FRONT REAR FRONT Figure 15 - Schematic Drawing of Cross-Connection Figure 16 - Rear Cross-Connect Cables with Tracer Wire Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 3-19...
  • Page 24: Dsx Card Front Patch

    Remove temporary patches in accordance with office procedures after permanent backplane cross-connections have been made. Figure 17 - Temporary Front Cross-Connect Using Patch Cables & DSX Cards Telect, Inc. • USA +1.509.926.6000 • Mexico +52.33.3836.37.52 www.telect.com • © 2010 Telect, Inc., All Rights Reserved, 139256 A0 Page 3-20...
  • Page 25: Chapter 4: Service

    Chapter 4: Service 4.1 Owner Maintenance Telect’s BCS 4R components do not need preventive maintenance. The only service you can perform is to replace these assemblies if they fail: • DSX Card Module • Repeater Card Module • DNI Card Module •...
  • Page 26: Out-Of-Warranty Service

    The procedure for out-of-warranty service is the same as for in-warranty service, except that Telect charges a processing fee, and you must submit a Purchase Order along with a Return Material Authorization (RMA) before returning equipment. Call a Customer Service Representative for help getting these forms.