  • Page 1 BULLSEYE ™ EXTINGUISHER SYSTEM USER’S MANUAL Version 3.0 01/19...
  • Page 3: Table Of Contents

    8.3.2 To change the way fire classes are displayed ........23 Using the web interface control .................24 8.4.1 Connecting an iOS device to the BullsEye panel ........24 8.4.2 Using the web interface control for conducting an evolution ....25 8.4.3 Using the scenario customization feature ..........27 8.4.4...
  • Page 4: How The Bullseye™ System Works

    The BullsEye Base Unit uses hundreds of LEDs and an on-board microprocessor to dynamically generate digital flames. Depending on the class of fire and level of difficulty selected by the instructor, the flames will grow, diminish and respond as the trainee attempts to extinguish the simulated fire.
  • Page 5 NOT alter laser module in any manner. Do not use this appliance without reading the entire User’s Manual and the user manual of Only direct the laser at the BullsEye Base Unit. any optional equipment. Do not direct at any other object or person.
  • Page 6: Important Safety Points

    Purchaser assumes all risk in the assembly and operation of this unit. Failure to follow this manual’s WARNINGS and instructions can result in severe personal injury, death, or property damage. LION is not responsible for any damage, death, or injury that may arise or result from improper or misuse of the BullsEye system.
  • Page 7: Bullseye Training System Parts & Accessories

    3. BULLSEYE TRAINING SYSTEM PARTS & ACCESSORIES* BullsEye is intended to provide safe and cost effective fire extinguisher training. NUMBER PART DESCRIPTION BullsEye Extinguisher Training System BullsEye Training Extinguisher 5 lb. (2,5 kg) BullsEye Training Extinguisher 10 lb. (6 kg) BullsEye Training Extinguisher 20 lb.
  • Page 8: Bullseye Training System Specifications

    BULLSEYE EXTINGUISHER SYSTEM ™ 4. BULLSEYE TRAINING SYSTEM SPECIFICATIONS PATENTED FEATURES SmartExtinguisher Air/water 40 kHz ultrasonic signal transmitting training extinguisher Extinguisher sensing Varies flames automatically based on SmartExtinguisher control system or BullsEye extinguisher input Common combustibles, Carbonatious, Flammable liquids, Flammable gases, and Electrical fire settings Difficulty level settings (levels 0–10)
  • Page 9 4 liters > 6 liters Volume/Trainee > 0.80 liters > 0.85 liters BULLSEYE SYSTEM EXTINGUISHER 40 khz integral distance sensing transducer Infrared signal with green laser display Maximum Output 4 mW Wave Length 532 nm Class 3R laser product Speaker simulating extinguishant discharge (max output: 75db)
  • Page 10: Product Information

    5. PRODUCT INFORMATION BULLSEYE SYSTEM The BullsEye Training System senses where the user aims and sweeps the laser- driven extinguisher and automatically varies the LED driven digital flames in response. Rugged stainless steel construction makes the BullsEye system highly portable. For training variation, the BullsEye system can also be used with the standard air/water SmartExtinguisher.
  • Page 11 BULLSEYE SYSTEM EXTINGUISHER TRANSPORT CASE This black industrial grade high impact plastic case can be used to conveniently transport two BullsEye system extinguishers. Locking latches provide safe and secure storage of the extinguishers when not in use. 7X SMARTEXTINGUISHER Rechargeable training extinguisher with pressure gauge and Schrader recharge valve.
  • Page 12: Optional Accessories

    • 5 lb. (2,5 kg) Dry Chem BullsEye system extinguisher • 10 lb. (6 kg) Dry Chem BullsEye system extinguisher •...
  • Page 13 Extinguishers, the Standard referenced by OSHA in developing its regulations. Covers everything from portable extinguisher basics to advanced strategies for workers in industrial environments. (17 min.) LION EXTINGUISHER TAMPER SEALS Lock your extinguisher handles in place for a realistic training experience with these tamper seals. Seals come 500 per package.
  • Page 14 BULLSEYE SYSTEM EXTINGUISHER TRANSPORT CASE This black industrial grade high impact plastic case can be used to quickly and easily transport BullsEye to and from various training sites. Includes built in wheels, custom foam and cutouts for controller and cables.
  • Page 15: Lion Service Plans

    7. LION SERVICE PLANS Need Assistance? Please see contact information on page 44. WWW.LIONPROTECTS.COM...
  • Page 16: Operating Instructions

    WARNING Any damaged parts must be replaced prior to operating the BullsEye system. Use of replacement parts that are not authorized by LION or are not original equipment parts supplied by LION will void the warranty. Do NOT attempt to adjust or service the laser module.
  • Page 17 Using these devices will void the warranty. WARNING If using the air/water SmartExtinguishers, you must attach the power cord extender and position the BullsEye to ensure that the power supply and GFCI outlet connection are in a dry environment at all times.
  • Page 18 BULLSEYE EXTINGUISHER SYSTEM ™ SETTING UP THE BULLSEYE SYSTEM LASER EXTINGUISHER 1. Place the hose into the hose clip. 2. Insert the pin into the handle. 3. Press the power switch under the hose, on the side of the extinguisher. The green power indicator light will turn on.
  • Page 19 The charger can be plugged into an outlet and the extinguisher then left overnight, but LION Group, Inc. does not recommend leaving the charger plugged in when not in use or leaving the charger connected for more than 24 hours.
  • Page 20 BULLSEYE EXTINGUISHER SYSTEM ™ CHANGING A BULLSEYE SYSTEM EXTINGUISHER BATTERY TO REPLACE A BATTERY WITHOUT A PLASTIC BOTTOM ON THE EXTINGUISHER 1. Turn the extinguisher upside down and remove the three Philips head screws holding the black battery cover in place.
  • Page 21 A power cord extender is also required when connecting the BullsEye to the power supply unit. To ensure that the BullsEye panel is positioned in a way that the power supply and power outlet connection remain in a dry environment.
  • Page 22 BULLSEYE EXTINGUISHER SYSTEM ™ WATER RECHARGE FOR THE 7X SMARTEXTINGUISHER 1. Ensure that the SmartExtinguisher is fully discharged of water and air. 2. Unscrew the headstock from the SmartExtinguisher. 3. Fill the SmartExtinguisher to 6 Liters using the funnel and measuring cup.
  • Page 23 • The gauge in Figure 5 shows that a SmartExtinguisher is under-pressurized and is not ready to be used with your BullsEye system base unit. • The gauge in Figure 6 shows a pressurized SmartExtinguisher, which is ready for use.
  • Page 24: Setting The Difficulty Level, Smoke Level And Volume Using The Standard Remote

    3. Press and hold the Adjustment button to rapidly change the setting. WARNING The BullsEye can simulate combustible materials, flammable liquids, flammable gas and electrical fires. The fires all respond differently to simulate the different kinds of fire. For example, combustible material fires respond by gradually diminishing with the proper application of extinguishant, while flammable liquid fires are easily “knocked...
  • Page 25: Language And Local Settings

    3. When simulating flammable gas and electrical fires, the fire will continuously reignite. In the case of a real electrical fire, the power must be turned off to prevent re-ignition. To simulate this, once the trainee tells the instructor that the power must be secured, the instructor can change the class to “a Common Combustibles fire”...
  • Page 26: Using The Web Interface Control

    CONNECTING AN IOS DEVICE TO THE BULLSEYE PANEL 1. Plug the BullsEye panel into the wall. When the BullsEye panel has started up and the blue indicator light is on, you will be able to connect your iOS device to the panel.
  • Page 27: Using The Web Interface Control For Conducting An Evolution

    4. To stop an evolution, press the red Stop button. 5. Select Flare Up or Die Down to increase or decrease the flames. 6. If using the BullsEye system with a Smoke Generator, select Smoke Burst to add smoke. 7. At the end of the evolution, adjust the settings as you wish, and simply press Start to begin again.
  • Page 28 Common Combustibles fire. An Electrical fire will not be extinguishable until the De-energize using electrical cutoff switch button has been pressed. If using a LION Electrical Cutoff Prop, the trainee can use the prop to simulate de-energizing the equipment and the fire will change to a Common Combustibles fire.
  • Page 29: Using The Scenario Customization Feature

    8.4.3 USING THE SCENARIO CUSTOMIZATION FEATURE 1. This software comes preloaded with several scenarios – Common Combustibles, Flammable liquids, Flammable gases, and Electrical fires. These scenarios are “read only” and cannot be changed or deleted. The software will refer to these as Classes or describe the type explicitly in accordance with your location setting.
  • Page 30 Cutoff Prop, leave the order as “not applicable”. If an activity order is selected and the required R.A.C.E. Station or Electrical Cutoff Prop is not linked to the BullsEye panel, the interface will show that the trainee failed the evolution.
  • Page 31 iv. Activities listed as “any” order must be conducted by the trainee before extinguishing the fire, but they can choose in which order to conduct them. Two activities with the same order number can be conducted in either order as long as they are done after activities with a lower order number and before activities with a higher order number.
  • Page 32: Importing And Exporting Scenarios Between Bullseye Panels

    IMPORTING AND EXPORTING SCENARIOS BETWEEN BULLSEYE PANELS To import or export scenarios to or from BullsEye panels, insert a USB Flash Drive in the port on the back of the panel. Select Import Scenarios or Export Scenarios from the “Settings”...
  • Page 33: Using The Training Record Management

    6. To stop recording training evolutions, toggle off the Tap to Record Training switch so it becomes gray. When setting up the scenario, having training toggled on or off. 7. When recording training evolutions, the BullsEye system automatically records the results at the end of the evolution.
  • Page 34: Updating Equipment Software

    2. Using an iPad or laptop with ad hoc Wi-Fi capabilities, connect to the Wi-Fi network named “Prop_Network”. 3. Connect to the BullsEye system using a web browser such as Firefox or Safari. Type the following into the address bar: bullseyeXXXX.net, where XXXX is the last four digits of the BullsEye system serial number found on the back of the BullsEye panel.
  • Page 35 LION equipment, such as the R.A.C.E. Station, Electrical Cutoff Prop, SG1000/VICO Smoke Generator and SG4000/ETNA Smoke Generator with a WiFi Adapter Box. Please note that this does not apply to BullsEye systems with serial numbers starting with 0705. Those systems do not have this capability.
  • Page 36 VICO Smoke Generator and BullsEye are not linked you will see “NO LINK” appear on the BullsEye. With the web interface software you will be able to make a smoke burst from the Training page and adjust the smoke level in the Settings page. If the SG1000/VICO Smoke Generator and BullsEye are not linked you will see “No Smoke...
  • Page 37 Please note that BullsEye systems with serial numbers starting with 0705 are not capable of linking. 2. Make sure the equipment you want to link and the BullsEye system are within WiFi range. To see if this is the problem, bring the equipment and BullsEye system to the same room and restart the power on each of them.
  • Page 38: Extinguisher Training With The Bullseye System

    TRAINING EVOLUTION PREPARATION 1. Ensure that the BullsEye system is properly set up. 2. Ensure that no personnel or items are in the vicinity of the BullsEye system. 3. Ensure that the trainee is prepared to “extinguish” the fire. 4. Ensure that the appropriate fire class, difficulty, volume and smoke settings have been selected.
  • Page 39 BullsEye system training extinguishers are most effective during the first several seconds of discharge. 8. The BullsEye system’s digital flames can be stopped at any time by pressing and releasing the STOP button. 9. For the next evolution, ensure that the training extinguishers are recharged.
  • Page 40: Shut Down Operation

    4. Wipe down all surfaces with a clean cloth and water and dry thoroughly. Use extra care when cleaning the ultrasonic (range finding) sensors. 5. Prepare the BullsEye system for transportation or storage by rotating the feet back into place. To do so, turn the feet so they are hidden under the BullsEye system.
  • Page 41: Bullseye System Transportation

    1. When transporting the BullsEye system, fold in the feet as completely as possible. To do so, rotate the feet to ensure that they are completely under the BullsEye system. The feet should be parallel to the front or back of the BullsEye system. If the feet are left extended they could become damaged.
  • Page 42: Maintenance System Operation

    • Surfaces of the appliance may be cleaned with a general non-abrasive household cleaner. Only clean the BullsEye system when it is NOT powered on, in use, or plugged • Do not use petroleum-based cleaners to clean any component of the appliance.
  • Page 43: Battery Disposal Information

    To prevent possible harm to the environment or human health, please separate this product from other waste to ensure that it can be recycled in an environmentally sound manner. For more details on available collection facilities please contact your local government office or LION at (see Contact Information page).
  • Page 44: Warranty Information

    ™ WARRANTY INFORMATION All parts such as stainless steel sheet metal components and controls are covered and LION will provide replacement parts free of charge during the warranty period. The warranty period shall begin on the ship date and continue for two full years. Batteries are covered under this warranty for a period of ninety days from the ship date.
  • Page 45 The original bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from LION or authorized dealer. LION reserves the right to have its representative inspect any product or part thereof prior to honoring any warranty claim.
  • Page 46: Contact Information

    BULLSEYE EXTINGUISHER SYSTEM ™ CONTACT INFORMATION LION North America | South America 7200 Poe Avenue, Suite 4000 Dayton, OH 45414, U.S.A. info@lionprotects.com 800-548-6614 (PPE) 888-428-5539 (Training) LION Europe | Middle East | Asia Industrieweg 5, 5111 ND Baarle-Nassau, The Netherlands infoEMEA@lionprotects.com...
  • Page 47 Do not look directly into beam or or maintenance can cause injury or property damage. view withtelescopic devices. Read the setup, operation and maintenance * THIS WARNING LABEL CAN BE FOUND ON THE BULLSEYE EXTINGUISHER. instructions thoroughly before installing or servicing this equipment. DANGER...
  • Page 48 BULLSEYE EXTINGUISHER SYSTEM ™ WWW.LIONPROTECTS.COM Manufactured in the USA © LION Group, Inc. All rights reserved. WWW.LIONPROTECTS.COM...