thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to
read, understand and comply with the following: You must check all
electrical products, before use, to ensure that they are safe. You must
inspect power cables, plugs, sockets and any other connectors for wear
or damage. You must ensure that the risk of electric shock is minimised
by the installation of appropriate safety devices. A residual current
circuit Breaker (rccB) should be incorporated in the main distribution
board. We also recommend that a residual current device (rcd) is
used. It is particularly important to use an rcd with portable products
that are plugged into a supply which is not protected by an rccB. If in
any doubt consult a qualified electrician. You may obtain a residual
current device by contacting your sealey dealer. You must also read
and understand the following instructions concerning electrical safety.
1.1.1. the Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance tester
(PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators. If in any
doubt about electrical safety, contact a qualified electrician.
1.1.3. ensure that the insulation on all cables and on the appliance is
safe before connecting it to the power supply. see 1.1.1. and
1.1.2. and use a Portable Appliance tester.
1.1.4. ensure that cables are always protected against short circuit
and overload.
1.1.5. regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none is loose.
1.1.6. Important: ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is fitted
with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician. When a Bs 1363/A uK 3 pin plug is
damaged, cut the cable just above the plug and dispose of the
plug safely.
fit a new plug according to the following instructions (uK only).
a) Connect the GREEN/YELLOW earth wire to the earth
terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that
InstructIons for:
DIRECT DRIVE COMPRESSOR
(90LTR/3.0HP)
SAC1903B
Model no:
SA1903B KEY:
1. compressor unit
2. Motor thermal reset button
3. electric motor
4. Pressure reducer
5. compressed air outlet
6. output pressure gauge
fig.1
all wires have been
correctly connected,
that the cable outer
insulation extends
beyond the cable
restraint and that the
restraint is tight.
double insulated
products, which are
always marked with
this symbol
fitted with live (brown)
and neutral (blue) wires
only. to rewire, connect
the wires as indicated in
diagram. DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without
a plug. In this case you must contact a qualified electrician to
ensure that a suitably rated supply is available. We recommend
that you discuss the installation of an industrial round pin plug
and socket with your electrician.
IMPORTANT! the use of extension leads to connect this
compressor to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump performance.
Original Language Version
7. tank pressure gauge
8. tank
9. Wheel
10. condensate drain valve
11. Pressure switch
12. check valve
13. Belt guard
Yellow & Green
Earth Wire
Blue
Neutral
Wire
, are
FUSE RATING 13 AMP
sAc1903B
Brown
Live
Wire
Cable
Restraint
Issue: 1 - 21/02/11

Advertisement

loading

Summary of Contents for Sealey SAC1903B

  • Page 1 SAC1903B Model no: thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 2.1. SPECIFICATION 1.2. GENERAL SAFETY Model: ................SAC1903B familiarise yourself with the application and limitations of the Motor output (HP): ................3 compressor. Voltage / Phase: .................230/1 ensure the compressor is in good order and condition before Input current: .................13A use. If in any doubt do not use the unit and contact an speed (rpm): ................1636...
  • Page 3 • replace oil • check cut-out • General cleaning of compressor • replace air filter • check tube fittings and electrical connections • Internal & external inspection of tank Original Language Version sAc1903B Issue: 1 - 21/02/11...
  • Page 4 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.