Alto-Shaam 1000-MR1 Operation And Care Manual
Alto-Shaam 1000-MR1 Operation And Care Manual

Alto-Shaam 1000-MR1 Operation And Care Manual

Mobile refrigerated cart
Hide thumbs Also See for 1000-MR1:

Advertisement

Quick Links

®
OPERATION and CAR E MAN UAL
Mobile Refrigerated Cart
Models: 1000-MR1
1000-MR2
COOK/HOLD/SERVE SYSTEMS
W 1 6 4 N 9 2 2 1 W a t e r S t r e e t
P. O . B o x 4 5 0
M e n o m o n e e F a l l s , W i s c o n s i n 5 3 0 5 2 - 0 4 5 0
U . S . A .
G
G
PHONE:
262.251.3800
FAX: 262.251.7067 • 800.329.8744
.
.
.
WEBSITE:
U
S
A
ONLY
800.558.8744
.
.
./
262.251.1907
www.alto-shaam.com
U
S
A
CANADA
INTERNATIONAL
.
.
.
#8410/11 • 3/2001
P R I N T E D I N U
S
A

Advertisement

Table of Contents
loading

Summary of Contents for Alto-Shaam 1000-MR1

  • Page 1 ® OPERATION and CAR E MAN UAL Mobile Refrigerated Cart Models: 1000-MR1 1000-MR2 COOK/HOLD/SERVE SYSTEMS W 1 6 4 N 9 2 2 1 W a t e r S t r e e t P. O . B o x 4 5 0 M e n o m o n e e F a l l s , W i s c o n s i n 5 3 0 5 2 - 0 4 5 0 U .
  • Page 2 START-UP PROCEDURE Refrigerant: 134a The refrigeration system is completely factory- assembled, precharged and ready for operation. Electrical: The control has been set to display temperature 1000-MR1 1000-MR2 in degrees Fahrenheit or degrees Celsius as specified on the original order. 115VAC 115VAC To energize the system, it is only necessary to 60 Hz, 1ø...
  • Page 3 21-1/4" (540mm) voltage stamped on 1000-MR2 unit FULL PERIMETER BUMPER nameplate WITH BUMPER 67-1/2" (1714mm) 64-1/2" (1638mm) 1000-MR1 on l POWER 2° off o 29-1/2" (749mm) WITH BUMPER 29-1/2" (749mm) 26-1/2" (673mm) on l POWER 2° off o Operation and Care Manual #8410/11 • 2...
  • Page 4 O P E R AT I O N / C L E A N I N G OPERATING PROCEDURES 5.1 CLEANING The purpose of this mobile refrigerator is to Follow appropriate state maintain cold foods at proper serving and local health (hygiene) temperatures.
  • Page 5: Maintenance

    S C H E D U L E D M A I N T E N A N C E 3. The thermostat is located behind the back 6.0 MAINTENANCE wall in the upper left corner of the unit and Remember to de-energize the unit by is clearly marked for adjustment purposes.
  • Page 6: Door Handle Replacement

    S C H E D U L E D M A I N T E N A N C E 6.6 DOOR HANDLE REPLACEMENT 1. Using a screwdriver, remove the three screws NOTE: It may be necessary to remove the which attach the butt section of the hinges to handle assembly in order to get the the cabinet.
  • Page 7 C O R R E C T I V E M A I N T E N A N C E T R O U B L E S H O O T I N G G U I D E S Y M P T O M P O S S I B L E F A I L U R E R E M E D Y...
  • Page 8: Refrigerant Leak

    These are the only service agents the adherence to limiting refrigerant charge company will authorize to repair Alto-Shaam ® amount to those specifically recommended units.
  • Page 9 S E R V I C E LOW PRESSURE CONTROL REPLACEMENT 7.3 FILTER DRYER REPLACEMENT 1. Disconnect the unit from the power source. Close liquid line valve and run compressor 2. Remove the control cover and disconnect the until the low-side refrigeration gauge electrical terminals.
  • Page 10 S e r v i c e P a r t s DESCRIPTION QUANTITY PART NUMBER DESCRIPTION QUANTITY PART NUMBER Caster, 6” (152mm), Rigid CS-2042 Handle, Push HD-2861 Caster, 6” (152mm), Swivel w/Brake CS-2231 Mullion Heater #1 L1HR161 - 115V Compressor RUT451 L1HR149...
  • Page 11 P a r t s I d e n t i f i c a t i o n SUCTION LINE BLOCK w/MANUAL STEM VALVE and ACCESS PORT OVERLOAD RELAY DISCHARGE LINE (4) MOUNTING FEET COMPRESSOR Compressor ITEM: Mobile Refrigerated Cart MODEL: DATE: 5-07-93...
  • Page 12 P a r t s I d e n t i f i c a t i o n Condensing Unit Detail ITEM: Mobile Refrigerated Cart MODEL: 5-06-93 DATE: REV: DWN BY: SCALE: ® MENOMONEE FALLS, WISCONSIN, U.S.A. Operation and Care Manual #8410/11 • 11...
  • Page 13 EVAPORATOR JUNCTION BOX DOOR HEATER 115V THERMOSTAT TRANSFORMER CONDENSING PRESSURE UNIT SWITCH 13 AMP FUSE DIGITAL THERMOMETER 115V, 60 Hz Electrical Schematic ITEM: Mobile Refrigerated Cart MODEL: 115VAC 6-16-98 DATE: REV: DWN BY: SCALE: ® MENOMONEE FALLS, WISCONSIN, U.S.A. EVAPORATOR JUNCTION BOX DOOR HEATER...
  • Page 14: Limited Warranty

    This warranty is 7. Save any packages and packing material for further inspection in lieu of all other warranties expressed or implied and Alto-Shaam, by the carrier. Inc. neither assumes or authorizes any persons to assume for it any other obligation or liability in connection with Alto-Shaam equipment.

This manual is also suitable for:

1000-mr2

Table of Contents