ICI Caldaie COSMOGAS AGUATANK 150 Instructions For Installation, Use And Maintenance Manual

Storage tank

Advertisement

Quick Links

MODELS:
AGUATANK 150
AGUATANK 200
AGUATANK 300
AGUATANK 500
AGUATANK 750
AGUATANK 1000

Advertisement

Table of Contents
loading

Summary of Contents for ICI Caldaie COSMOGAS AGUATANK 150

  • Page 1 MODELS: AGUATANK 150 AGUATANK 200 AGUATANK 300 AGUATANK 500 AGUATANK 750 AGUATANK 1000...
  • Page 3: Table Of Contents

    INDEX 1 - GENERAL INFORMATION ..................4 1.1 - General safety warnings ......................4 1.2 - National installation laws ......................4 1.3 - Introduction ..........................5 1.4 - Overview of the models ......................5 1.5 - Meaning of the symbols used ....................5 2 - MAIN COMPONENTS ....................
  • Page 4: General Information

    1 - GENERAL INFORMATION 1.1 - General safety warnings Installation, changes Technical drawings  The installation must be carried out by a professionally  All drawings in this manual relating to electrical, hydraulic qualified technician, in compliance with the national and or gas installation systems, are purely indicative.
  • Page 5: Introduction

    1 - GENERAL INFORMATION 1.3 - Introduction Congratulations! You have purchased truly one of the best products on the market. Every single part is proudly built, tested and assembled at the COSMOGAS plants, thereby ensuring the best quality control. 1.4 - Overview of the models AGUATANK XXX = 150 litre capacity floor standing tank.
  • Page 6: Main Components

    2 - MAIN COMPONENTS 2.1 - AGUATANK 150 Main 1 - Magnesium anode (1” 1/2); from 2 to 9 - Fitting input/output (1” 1/2); components from 11 to 15 - Probe well (1/2”); 16 - Ø 300 mm Inspection flange; 17 - Supply fitting from solar circuit (1”) * 18 - Return fitting to solar circuit (1”) * ATTENTION !!! It is advisable for the installer to...
  • Page 7: Aguatank 200 And 300 Main Components

    2 - MAIN COMPONENTS 2.2 - AGUATANK 200 and 300 1 - Magnesium anode (1” 1/2); from 2 to 9 - Fitting input/output (2”); Main components 10 - Thermometer well (1/2”); from 11 to 15 - Probe well (1/2”); 16 - Ø 300 mm Inspection flange; 17 - Supply fitting from solar circuit (1”) * ATTENTION !!! It is advisable for the installer to 18 - Return fitting to solar circuit (1”) *...
  • Page 8: Aguatank 500 Main Components

    2 - MAIN COMPONENTS 2.3 - AGUATANK 500 Main 1 - Magnesium anode (1” 1/2); from 2 to 9 - Fitting input/output (2”); components 10 - Thermometer well (1/2”); from 11 to 15 - Probe well (1/2”); 16 - Ø 300 mm Inspection flange; 17 - Supply fitting from solar circuit (1”) * ATTENTION !!! It is advisable for the installer to 18 - Return fitting to solar circuit (1”) *...
  • Page 9: Aguatank 750 And 1000 Main Components

    2 - MAIN COMPONENTS 2.4 - AGUATANK 750 and 1000 1 - Plug (1” 1/2); from 2 to 9 - Fitting input/output (2”); Main components 10 - Thermometer well (1/2”); from 11 to 15 - Probe well (1/2”); 14 - Electronic protection anode 16 - Ø...
  • Page 10: Operation

    3 - OPERATION 3.1 - Installation examples Below are some examples of connection diagrams of water heaters, boilers and AGUATANK tanks: Example of connection between AGUADENS 16 or 22 model water heater and AGUATANK tank (See fig. 3-1). Figure 3-1 KEY ---------- AGUADENS 16 or 22 water heater ----------...
  • Page 11 3 - OPERATION Example of connection between boiler water heater and AGUATANK tank used as PUFFER (See fig. 3-2). Figure 3-2 KEY ---------- Heating only COSMOGAS boiler ---------- Recirculation pump (installer’s responsibility) ---------- Boiler supply ---------- Gas inlet ---------- Boiler return Possible expansion tank for heating circuit AGUATANK model tank (to be provided by the installer)
  • Page 12 3 - OPERATION Example of connection between AGUADENS 37 model water heater and AGUATANK type tank (See fig. 3-3). Figure 3-3 KEY 37 AGUADENS model water heater INAIL safety valve (on request) Recirculation pump (installer’s responsibility) INAIL manometer (on request) Water heater hot water outlet INAIL thermometer (on request) Gas inlet...
  • Page 13 3 - OPERATION Example of connection between AGUADENS 60T-280T model domestic hot water producer and AGUATANK type tank (See fig. 3-4). Max 1 metre Figure 3-4 KEY INAIL well (on request) AGUADENS 60T-280T INAIL safety valve (on request) model domestic hot water producer INAIL manometer (on request) Recirculation pump (installer’s responsibility) INAIL thermometer (on request)
  • Page 14: Installation

    4 - INSTALLATION 4.1 - Dimensions and minimum distances to respect Free space must be left around the appliance both for installation and maintenance, as illustrated in figure 4-1. Figure 4-1 - Storage tanks minimum distances to respect Figure 4-2 - AGUATANK 150 tank sizes (numeric references in chapter 2.1)
  • Page 15 4 - INSTALLATION Figure 4-3 - AGUATANK 200 tank sizes (numeric references in chapter 2.2)
  • Page 16 4 - INSTALLATION Figure 4-4 - AGUATANK 300 tank sizes (numeric references in chapter 2.2)
  • Page 17 4 - INSTALLATION Figure 4-5 - AGUATANK 500 tank sizes (numeric references in chapter 2.3)
  • Page 18 4 - INSTALLATION Figure 4-6 - AGUATANK 750 tank sizes (numeric references in chapter 2.4)
  • Page 19 4 - INSTALLATION Figure 4-7 - AGUATANK 1000 tank sizes (numeric references in chapter 2.4)
  • Page 20: Choosing The Installation Site

    4 - INSTALLATION 4.2 - Choosing the installation site ATTENTION !!! The appliance must only be installed on a horizontal surface that withstands its weight. Consider the weight of the tank in service (see chapter 7 technical features) plus the water heater if of the floor standing type, both full of water (see the water heater installation manual for its references).
  • Page 21: Positioning The Temperature Probes

    4 - INSTALLATION 4.3 - Positioning the AGUATANK 200 and 300 Tank (without auxiliary exchanger): temperature probes A - Thermometer B - ---------- C - Boiler Probe ATTENTION !!! For the proper operation of the D - Boiler Probe system, check that the probes are correctly positioned E - ---------- in the different models as shown in the figures.
  • Page 22 4 - INSTALLATION AGUATANK 500 Tank AGUATANK 750 and 1000 Tank (without auxiliary exchanger): (without auxiliary exchanger): A - Thermometer A - Thermometer B - ---------- B - Boiler Probe C - Boiler Probe C - Boiler Probe D - D.H.W. Producer or Water Heater or Boiler Probe D - D.H.W.
  • Page 23: Tank Drain Cock (Installer's Responsibility)

    4 - INSTALLATION 4.4 - Tank drain cock (installer’s responsibility) ATTENTION !!! For the safety valve in the water heater, please refer to the relevant chapter in its It is advisable to install a cock to help drain the tank installation manual.
  • Page 24: Maintenance

    5 - MAINTENANCE 5.1.2 - Emptying the appliance 5.1 - Maintenance To empty the appliance, proceed as follows:  close the main domestic cold water supply cock of the ATTENTION!!! home; The appliance must only be serviced by a professionally ...
  • Page 25: Use

    6 - USE 6.1 - Important information 6.7 - Precautions against frost The appliance is not protected against frost. In case of shutdown, if this can be exposed to temperatures below zero, ATTENTION !!! the system must be emptied as described in chapter 5.1.2; Please note that the assembly, adjustment and maintenance of the electrical and hydraulic 6.8 - Anomalies during...
  • Page 26: Technical Features

    7 - TECHNICAL FEATURES AGUATANK TECHNICAL FEATURES Destination country ITALY ITALY Capacity Heating fluid Water Water Heated fluid Water Water Lower auxiliary exchanger on request on request Auxiliary exchanger material Tinned copper Tinned copper Auxiliary exchanger thickness Exchange surface of the auxiliary exchanger 1,53 1,53 Material for foundations, plating and fittings...
  • Page 27 7 - TECHNICAL FEATURES 1000 ITALY ITALY ITALY ITALY 1000 Water Water Water Water Water Water Water Water on request on request on request on request Tinned copper Tinned copper Tinned copper Tinned copper 1,53 1,53 1,53 1,53 Fe 360 Steel Fe 360 Steel Fe 360 Steel Fe 360 Steel...
  • Page 28: Ce Declaration Of Conformity

    8 - CE DECLARATION OF CONFORMITY The undersigned company, CSOSMOGAS S.r.L., with registered office in via L. Da Vinci no. 16 - 47014 Meldola (FC) ITALY, DECLARES under its own responsibility that the product: WARRANTY NO. APPLIANCE MODEL DATE OF MANUFACTURE subject of this declaration, is compliant with the requirements of Directives: Low Voltage (2006/95/EC) and Electromagnetic Compatibility, (2004/108/ EEC).
  • Page 32 COSMOGAS s.r.l. Via L. da Vinci 16 - 47014 MELDOLA (FC) ITALY info@cosmogas.com www.cosmogas.com...

Table of Contents