Tait T800 II Series Service Manual

Tait T800 II Series Service Manual

Ancillary equipment

Advertisement

1
M800-00
T800 Series II
Ancillary Equipment
Service Manual
Issue 101
May 1998
M800-00-101
Copyright TEL
30/04/98

Advertisement

Table of Contents
loading

Summary of Contents for Tait T800 II Series

  • Page 1 M800-00 T800 Series II Ancillary Equipment Service Manual Issue 101 May 1998 M800-00-101 Copyright TEL 30/04/98...
  • Page 2 Phone: 64 3 348-3301 Fax: 64 3 343-0558 Australia Singapore Tait Electronics (Aust) Pty Ltd 186 Granite Street Tait Electronics (Far East) Pte Ltd Geebung Qld 4034 4 Leng Kee Road P.O. Box 679 SIS Building #05-11A Virginia Singapore 159088...
  • Page 3: About This Manual

    If you return the address card at the front of this manual, you will be notified when revision packages containing new PCB information and/or text are available. You may then order as many packages as you require from your local Tait Company. Revision packages are supplied ready-punched for inclusion in your manual.
  • Page 4: Technical Information

    Technical Information Any enquiries regarding this manual or the equipment it describes should be addressed in the first instance to your nearest approved Tait Dealer or Service Centre. Further technical assistance may be obtained from the Customer Support Group, Radio Systems Division, Tait Electronics Ltd, Christchurch, New Zealand.
  • Page 5 M800-00 Table Of Contents This manual is divided into three parts as listed below, with each part being further sub- divided into sections. There is a detailed table of contents at the start of each part and/or section. Part Title General Servicing Procedures T807/808 Switching Power Supply T800-22-0000 Base Station/Repeater Rack Frame...
  • Page 6 M800-00 List Of Effective Pages The total number of pages in this Manual is 195, as listed below. Page Issue Date Page Issue Date 30/04/98 31/08/96 30/04/98 31/08/96 30/04/98 31/08/96 30/04/98 31/08/96 30/04/98 1.10 31/08/96 (blank) 30/04/98 30/04/98 31/08/96 30/04/98 (blank) 31/08/96 (blank) 31/08/96 31/08/96...
  • Page 7 M800-00 Page Issue Date Page Issue Date 31/08/96 8.2.39 31/08/96 (fold-out) 31/08/96 (blank) 8.2.40 31/08/96 (fold-out) 31/08/96 8.2.41 31/08/96 (fold-out) 31/08/96 8.2.42 31/08/96 (fold-out/blank) 31/08/96 8.2.43 30/11/97 8.2.44 31/08/96 31/08/96 31/08/96 8.2.45 31/08/96 (blank) 31/08/96 8.2.46 30/11/97 8.2.47 31/08/96 (fold-out) 8.1.1 31/08/96 8.2.48...
  • Page 8 M800-00 3.1.1 30/04/98 3.1.2 30/04/98 (blank) 3.1.3 30/04/98 3.1.4 30/04/98 (blank) 3.2.1 30/04/98 3.2.2 30/04/98 (blank) 3.2.3 30/04/98 3.2.4 30/04/98 3.2.5 30/04/98 3.2.6 30/04/98 3.2.7 30/04/98 3.2.8 30/04/98 3.2.9 30/04/98 3.2.10 30/04/98 3.2.11 30/04/98 (fold-out) 3.2.12 30/04/98 (fold-out) 3.2.13 30/04/98 (fold-out) 3.3.1 30/04/98 3.3.2...
  • Page 9 M800-00 Part A General Servicing Procedures This part of the manual is divided into the sections listed below. These sections provide some general and advisory information on servicing procedures, a brief history of T800 programming software, and a list of Technical Instructions pertaining to T830 Series equipment.
  • Page 10 M800-00 31/08/96 Copyright TEL...
  • Page 11 Tait Electronics Ltd or accredited agents. When requesting this infor- mation, please quote the equipment type number (e.g. T807-10) and serial number. In the case of the Service Manual quote the Tait Internal Part Number (IPN), e.g. M800-00- 100, and for circuit diagrams quote the 'Title', 'IPN' and 'Issue'.
  • Page 12 A1.2 General M800-00 Caution: Beryllium Oxide & Power Transistors The power transistors in current use all contain some beryllium oxide. This substance, while perfectly harmless in its normal solid form, can become a severe health hazard when it has been reduced to dust. For this reason the power transistors should not be broken open, mutilated, filed, machined, or physically damaged in any way that can produce dust particles.
  • Page 13: Pozidriv Recess Head Screws

    Mechanical Pozidriv Recess Head Screws Pozidriv recess head screws are the preferred standard on all Tait manufactured equip- ment. The very real advantages of this type of screw will not be realised unless the cor- rect screwdrivers are used by servicing personnel.
  • Page 14 A2.2 Mechanical M800-00 31/08/96 Copyright TEL...
  • Page 15: Component Replacement

    Component Replacement A3.1 M800-00 Component Replacement Leaded Components Whenever components are removed from or fitted to a PCB, care must be taken to avoid damage to the track. The two satisfactory methods of removing components from PTH PCBs are detailed below. Note: The first method requires the use of a desoldering station, e.g.
  • Page 16: Surface Mount Devices

    Surface mount devices (SMDs) require special storage, handling, removal and replacement techniques. This equipment should be serv- iced only by an approved Tait Dealer or Service Centre equipped with the necessary facilities. Repairs attempted with incorrect equipment or by untrained personnel may result in permanent damage. If in doubt, contact Tait Electronics Ltd or your nearest Tait Branch or Subsidiary.
  • Page 17 To Remove Cased Mica Capacitors A4.1 M800-00 To Remove Cased Mica Capacitors Cased mica capacitors can be removed by heating the top with a heavy-duty soldering iron and gently lifting the capacitor off the PCB with a solder-resistant spike or equiva- lent.
  • Page 18 A4.2 To Remove Cased Mica Capacitors M800-00 31/08/96 Copyright TEL...
  • Page 19: Software History

    Software History A5.1 M800-00 Software History 23/11/89 BASEPROG Version 1 23/08/90 PGM800 Version 2 11/06/91 PGM800 Version 2.01 03/10/95 PGM800 Version 2.21 28/06/96 PGM800Win Version 1.00 18/08/97 PGM800Win Version 2.00 BASEPROG V1/PGM800 V2 T800 programming software was originally developed as BASEPROG V1 and released as PGM800 V2.
  • Page 20 A5.2 Software History M800-00 PGM800 V2.21 PGM800 V2.21 is an updated and expanded version of the earlier PGM800 V2.01 soft- ware. PGM800 V2.21 includes many new and improved features over PGM800 V2.01. There are a number of changes to the user interface to make data entry and editing signifi- cantly easier.
  • Page 21 Software History A5.3 M800-00 Note: The datafiles produced by BASEPROG V1.0 and all DOS versions PGM800 are still compatible with PGM800Win V1.00. PGM800Win v2.00 PGM800Win V2.00 is an upgraded and expanded version of PGM800Win V1.0. It has been developed specifically for T800 Series II base stations but also has the capability of programming Series I equipment.
  • Page 22 A5.4 Software History M800-00 31/08/96 Copyright TEL...
  • Page 23: Technical Instructions

    Technical Instructions From time to time Technical Instructions (TIs) are issued by the Radio Infrastructure Engineering Division of Tait Electronics. These TIs may be used to update equipment or information, or to meet specific operational requirements. TIs applicable to specific T800 Series ancillary equipment are listed in the relevant part of this manual.
  • Page 24 A6.2 Technical Instructions M800-00 31/08/96 Copyright TEL...

This manual is also suitable for:

T807 iiT808 ii

Table of Contents