Summary of Contents for Viessmann VITOTHERM EI5 Series
Page 1
Operating instructions for system users Vitotherm EI5 Version EI5.A3 K Version EI5.A5 K Electric instantaneous water heaters VITOTHERM EI5 6167204 GB 11/2020 Please retain for future use...
Page 2
Safety instructions For your safety Before commissioning and operating the appliance, please read the documents enclosed with the appliance. Follow the safety instructions closely to prevent hazards, injury and material losses. Store the supplied documents in a safe place. Safety instructions explained Danger Note This symbol warns against the...
Page 3
Safety instructions For your safety (cont.) Working on the appliance Cleaning the appliance ■ Clean the exterior of the appliance ■ All settings and work on the appliance with a commercially available must be performed as specified in domestic cleaning agent. these operating instructions.
Page 4
Safety instructions For your safety Operation of the appliance Installation room requirements ■ Danger For showers, the DHW temperature must not exceed 55 °C. Easily flammable liquids and If necessary, have safety equipment materials (e.g. naphtha/petrol, installed to prevent scalding. solvents, cleaning agents, paints or ■...
Page 5
Safety instructions For your safety (cont.) If water escapes from the appliance Faults on the appliance Danger ■ Isolate the appliance from the power If there are leaks in the appliance, supply, e.g. at the separate fuse or there is a risk of electric shock. a mains isolator.
Page 6
Operating instructions Intended use The appliance is used for the heating of Any use that differs from or goes beyond this domestic hot water and can supply one or is considered inappropriate. more draw-off points as applicable. Intended use also extends to compliance with these instructions and with the instructions for The appliance is intended for domestic use.
Page 7
Operating instructions Specification Electric instantaneous water heaters EI5.A3 K EI5.A5 K Rated voltage 230 V~ Rated output Power consumption 15.2 23.9 Flow rate (at Δt = 30 K) l/min Rated voltage 220 V~ Rated output Power consumption 14.5 22.7 Flow rate (at Δt = 30 K) l/min Flow pressure 0.12 ÷...
Page 8
Viessmann Werke GmbH & Co. KG D-35107 Allendorf Phone: +49 (0)6452 70-0 Copyright: Viessmann Poland. The reproduction, copying or use of this document Fax: +49 (0)6452 70-2780 or parts thereof without the consent of the author is not permitted. 10/2020...
Need help?
Do you have a question about the VITOTHERM EI5 Series and is the answer not in the manual?
Questions and answers