Perform Tests; Viewing The Event Log; Enabling The Chime Function - Siemens SPCK420 User Manual

Hide thumbs Also See for SPCK420:
Table of Contents

Advertisement

6.4

Perform Tests

6.5

Viewing the Event Log

6.6

Enabling the Chime Function

Siemens Building Technologies
Fire Safety & Security Products
Tests can be performed on the system to determine if bells, buzzers, and other
audible devices operate correctly.
To perform a test on the system:
1.
Scroll to the TEST option and press SELECT
(right soft key).
2.
Scroll and select BELL TEST, WALK TEST,
or AUDIBLE OPTIONS.
3.
When BELL TEST is selected, users may test
each device by pressing NEXT for external
bells, strobe, internal bells, or buzzer. The
device sounds for each to verify it is operating
correctly.
4.
When WALK TEST is selected, users can test
the operation of each alarm device by
activating the device and listening for audible beeps at the Keypad.
The most recent events on the system can be viewed by selecting the EVENT
LOG option. The most recent events display on the bottom line with previous
events displaying for one second in turn.
To view the event log on the Keypad:
1.
Scroll to the EVENT LOG option and press
SELECT (right soft key).
The Keypad displays the recent events on the
system on the bottom line display for one
second in turn.
2.
To view an event from a particular date, enter
the date with the numeric keys.
The chime function can be enabled or disabled on all zones where the chime has
been programmed as an audible alert feature.
To enable or disable the chime function:
1.
Scroll to the CHIME option and press
SELECT (right soft key).
2.
Toggle between enable or disable for the
chime function.
User Menu Options
...TEST...
EXIT
SELECT
...BELL TEST...
BACK
SELECT
EXT BELL
BACK
NEXT
...EVENT LOG...
EXIT
SELECT
21 Apr 08
12:30
WALKTEST BY USER
DATE
18/04/2008
BACK
ENTER
...CHIME...
EXIT
SELECT
...ENABLED...
BACK
SELECT
09.2008
19