Brüel & Kjær Vibro │Instruction VST-100 Contents Contents Safety Instructions ....................4 Disclaimer of Liability ........................... 4 Pictograms and their Meanings ......................4 User Qualification ..........................4 Intended Use ............................5 Recommendations to User ........................6 General Hints ............................6 Overview ........................
Safety Instructions Disclaimer of Liability The observance of this technical documentation is essential for the proper and safe operation of the product. We assume no liability for injury to persons, damage to property or financial losses resulting from failure to comply with this technical documentation. In this case the liability for material defects is also excluded.
Brüel & Kjær Vibro │Instruction VST-100 Safety Instructions Intended Use If devices, sensors and cables are used in a way not described in the relevant user manuals, function and protection may be impaired and serious personal damage, death or serious, irreversible injuries may result.
Hot surfaces In line with the user manuals, the devices, sensors and cables can be operated in extensive ambient temperature ranges, whereby they can become hot through self-heating on housing walls and can produce burning. When mounted at external heat or cold sources (e.g. machine parts), devices, sensors and cables can adopt dangerous temperatures, whereby burning, among other things, can occur in the event of contact.
Overview Overview The VIBROSTORE 100 (VST-100) is a simple to use rugged vibration monitoring and portable analysis instrument with on-board display of vibration levels. VST-100 automatically performs vibration analysis functions based on machine running speed. This functionality can help diagnose faults such as unbalance, misalignment and looseness.
Batteries The VST-100 requires two type AA size batteries, which are replaced by removing the protective rubber boot first and second the battery compartment cover (held in place by multiple screws) as shown in the photographs below: L91 lithium-Ion type AA batteries are recommended. For installing new batteries, please remove all empty batteries first, before installing new or fully charged batteries.
Brüel & Kjær Vibro │Instruction VST-100 Operation Operation Basic Operation Standard BNC connector for Color coded display shows ISO IEPE accelerometers. value, bearing condition in Bearing Damage Units (BDU) and RMS acceleration (g). ISO and BDU values are alarm colour coded in Green, Yellow Red.
Menu navigation Live Update (starts a repeated measurement) Motor Size Foundation Under 300kW Flexible Run Speed Machine Type Over 300kW Rigid 1500 RPM Motor Pump Pump Type Foundation Integrated Drive Flexible External Drive Rigid Configuration Manual Setup ISO Alarms Alert Live Update ISO Alarms Alert...
Page 11
Brüel & Kjær Vibro │Instruction VST-100 Operation Menu navigation (continuation) Configuration Enter by holding Live Update the center Setup Wizard button for 2 Manual Setup Seconds Device Settings Device Settings Auto Off Time Brightness Languages Factory Reset Factory Reset Graph Mode Metric Colour Scheme Imperial...
Page 12
Menu navigation (continuation) Machines [Machine 1] [Meas. Point 1] Enter by [Machine 1] [Meas. Point 1] Take Measurement holding the [Machine 2] [Meas. Point 2] Run Speed factory [Machine 3] [Meas. Point 3] Save Measurement button [Machine 4] [Meas. Point 4] Load Measurement Bluetooth Config Paired Devices...
Brüel & Kjær Vibro │Instruction VST-100 Operation Fitting the sensor VST-100 is supplied with a cable connected sensor (accelerometer) that connects to the BNC connector on VST-100. The nominal sensitivity of the sensor is 100 mV/g. VST-100 can also accept any standard IEPE (CCS) accelerometer and the sensor sensitivity setting can be adjusted to accommodate other sensitivities (see section 3.5.2.3 in this manual).
Taking a reading To take a reading, press the center button turn the unit ON. Place the sensor on a rigid part of the machine as close as possible to the desired measurement point (e.g. bearing block) using the magnet mount. Pressing the circle button again takes the reading.
Brüel & Kjær Vibro │Instruction VST-100 Operation 3.4.1 Vibration readings WARNING! Through electro-magnetic interferences (acc. to EN 61000-4-3) influences on the measured values may arise. Once a vibration reading has been taken, the display will show three values, as shown in the example screen (see chapter 3.4 Taking a reading).
Page 16
ISO value (mm/s) The ISO value (in mm/s or inch/s) is the large number displayed at the top of the screen. This is the RMS measurement of the calculated peak measurement of the vibration velocity in the frequency band 10Hz (600 RPM) to 1kHz (60,000 RPM) or 2Hz (120 RPM) to 1kHz (60,000 RPM) as specified by the ISO standard .
Brüel & Kjær Vibro │Instruction VST-100 Operation Bearing Condition (BDU) Below the displayed ISO value and to the left is the value of bearing noise(high frequency vibration) in Bearing Damage Units (BDU), where 100 BDU corresponds to 1 g RMS vibration measured in the frequency band between 1kHz and 10kHz.
Page 18
N.B. in order to perform a vibration analysis it is important that the running speed of the machine is entered correctly. This can be done with the “Setup Wizard” as described in Section 3.5.1 of this user guide, or by using the strobe attachment (see Section 6.1) Typical but not exclusive for the appearance of following multiples of running speed are:...
Brüel & Kjær Vibro │Instruction VST-100 Operation 3.4.3 Frequency spectrum Pressing the down arrow button once more brings up a display, where the vibration levels are shown as a frequency spectrum plot in the range from 0 to 1 kHz. The heights of the peaks indicate the RMS vibration level (in mm/s or inch/s) at each frequency point in the spectrum.
Configuration menus The configuration menu is entered by pressing and holding down the center button for 2 seconds. Moving up and down the menu is achieved by pressing the up and down buttons which causes the menu item to be highlighted. Pressing the circle button will select the highlighted menu item.
Page 21
Brüel & Kjær Vibro │Instruction VST-100 Operation Pressing the center button again brings up the next screen which allows the machine type (motor or pump) to be selected. If a motor is selected the size must also be selected (under or over 300 kW) or if a pump is selected, it must be specified whether it has an integrated or external drive unit.
3.5.2 Manual Setup 3.5.2.1 BDU alarm settings Selecting BDU Alarms allows the alarm levels at which the BDU readings change color to be altered by the user. Normal levels are displayed on a Green background. The BDU threshold values are designated as ALERT (where readings turn Yellow) and DANGER (where readings turn Red).
Brüel & Kjær Vibro │Instruction VST-100 Operation 3.5.2.3 Sensor mV/g Accelerometer sensitivity (in mV/g) can be manually set using the up and down arrow buttons to allow the use of any desired sensor within the range 1mV/g to 1000mV/g. This enables the resolution and range of the VST-100 to be set by the user.
Page 24
The Auto Off Time can be set from 1 minute up to a maximum value of 60 minutes, in increments of 1 minute. The Brightness level can be set anywhere between 1 (least brightness) up to 10 (full brightness). The operating Language can be selected depending on the exact model. Please refer to the product specifications.
Brüel & Kjær Vibro │Instruction VST-100 Route Management Route Management Pressing the Route Manager button (industry icon , located just below the down arrow button) brings up the Machines menu. Machines have user-defined names up to 16 characters long. Scrolling the list of machines is achieved with the up and down arrow buttons.
ReO Software ReO is the PC based software that allows users to view trends of vibration readings taken with VST-100, in a way that enables predictions to be made about machine condition. ReO is very powerful and highly functional route editor and analysing software, which is described in more detail in its own instruction manual.
Brüel & Kjær Vibro │Instruction VST-100 Optional accessories Optional accessories AC-7315 Strobe attachment Pressing the top left strobe button brings up the run speed display and causes the strobe to flash at the displayed rate. The flash rate can be increased or decreased with the up and down arrow buttons and the run speed will simultaneously update.
Third party Bluetooth headphones Pressing the headphones button (top right button) the Bluetooth mode is enabled and allows the VST-100 to wirelessly connect to a set of Bluetooth earphones. Bluetooth is deactivated after restarting the device or by pressing the headphone button again. Other active Bluetooth devices might disturb the process of connecting your headphones.
Brüel & Kjær Vibro │Instruction VST-100 Specification Specification Size 200 mm x 60 mm x 26 mm Weight 280 g Environmental Degree of Protection IP67 Operating: 0 °C to 50 °C (32 °F to 122 °F) Storage: -20 °C to 70 °C (-4 °F to 158 °F) Power supply 2 x AA L91 lithium-ion batteries Battery life...
Maintenance HINT! Maintenance and service work must only be performed by trained qualified personnel! 1. Clean the device on the outside in regular intervals using a damp cloth. 2. Ingress of humidity, i.e. from water or other liquids, into the device must be prevented! Disposal The device is subject to the Waste Management Act for electrical and electronic devices.
Need help?
Do you have a question about the VIBROSTORE 100 and is the answer not in the manual?
Questions and answers