Page 1
Multi station Multi station Art. No. : 23066REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Device is not suitable for disconnection from supply voltage. For parallel connection of several motors to an output it is essential to observe the corresponding instructions of the manufacturers, and to use a cut-off relay if necessary.
Page 2
3 Function System information This device is a product of the KNX system and complies with the KNX directives. Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding. The function of this device depends upon the software. Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer´s product database.
Page 3
Multi station Heating controller 2 internal controllers to control two independent rooms Control for heating or cooling operation, optionally with additional level Two-point, PWM or PI control Predefined heating types (hot water heating, blower convector, etc.) or individual parameters possible Inputs 6 inputs for push-buttons Input functions switching, dimming, shutter control, light scene extension unit, brightness or...
Page 4
Multi station Fitting the device Observe the temperature range. Ensure adequate cooling. Mount the device on DIN rail. Output terminals must be at the top. Connecting the device Figure 2 Connect bus line with connecting terminal. Attach the cover cap to the bus cable connection as protection against hazardous voltages. For switched loads, configure the outputs as a switching output.
Page 5
Write the physical address on the device label. Load the application software into the device. 6 Technical data KNX medium TP 256 Commissioning mode S-mode Rated voltage KNX DC 21 ... 32 V SELV Current consumption KNX max. 20 mA Current consumption KNX min. 4 mA Connection type for bus...
Page 6
Multi station Switching current AC1 16 A Switching current AC3 6 A Fluorescent lamps 16 AX Switch-on current 200 µs max. 800 A Switch-on current 20 ms max. 165 A Switching voltage DC DC 12 ... 24 V Switching current DC 24 V 6 A Connected load 230 V Ohmic load 3000 W Blind, fan motors...
Page 7
Multi station ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de www.jung.de 82596803 26.01.2017 j0082596803...