Download Print this page

Signal Strength; Factory Reset - G.S.M Activate SWV2G-RS2 Manual

Gsm 2g/3g 240v roller shutter opener

Advertisement

Using your mobile phone or landline, dial the simcard number within the unit. You will hear
two ring tones. The unit will then answer the call. Once the call is open you can use the
keypad on your phone to operate the device.
Pushing key number 1 or 2 again will stop the command and the shutter will hold in a
stationary position.
We recommend connecting relay 1 to OPEN/UP and relay 2 to CLOSE/DOWN on your
roller shutter control board.
When you press 1 you will hear a fast dialling tone.
When you press 2 you will hear a slower dialling tone.
Please view the diagram on page 6 for wiring information.
This function is used for roller shutter control boards whereby you need to manually hold
the button to open or close the roller shutter. Once you remove your finger from the button
the roller shutter will stop the operation your are performing.
To use the roller shutter opener in this mode (latching relay) you need to put dipswitch 2
to the ON position. The relay will now latch on for 15 seconds instead of pulsing.
Pressing key 1 will cause relay 1 to pulse to open for 15 seconds
Pressing key 2 will cause relay 2 to pulse to close for 15 seconds
Pressing key 3 will cancel the command and stop the shutter.
To help make sure that you place the unit in a suitable position you can text the unit to see
how much signal strength the dialler is receiving by texting the command
#SIGNAL
The unit will perform a test on the signal strength.
You will receive a text telling you the signal strength score between 0-30. We strongly
recommend that you place the unit where you will receive a score of at least 10. You will
find that a signal strength score of less than 10 will make the unit unreliable.
To perform a quick factory reset which will delete ALL of your stored numbers please send
the text command
#RESET
The
red
LED will flash 6 times indicating that the reset has been successful.
How to use the Roller Shutter Opener
Press key 1 - Relay 1 will pulse
Press key 2 - Relay 2 will pulse
Latching Relay - Deadmans Button

Signal Strength

Factory Reset