Important notes Important notes The filter may be used in an area with the poten- tially explosive atmosphere of zones 1, 2 and 21, Information on the installation manual This manual enables operating or service personnel Explosion protection labelling: to correctly install the product described below and to use it safely and efficiently.
Section VI, Warranty Claims, of the Delivery and Payment Terms of TROX GmbH. Danger due to incorrect use! The Delivery and Payment Terms of TROX GmbH Misuse of the filter can lead to dangerous situa- are available at www.troxtechnik.com. tions.
Supply package, transport and storage Protective gloves Supply package, transport and storage Supply package Casing Filter element (optional) Transport Protective gloves protect hands from friction, abra- sions, punctures, deep cuts, and direct contact with hot surfaces. CAUTION! Danger of injury from sharp edges, sharp cor- ners and thin sheet metal parts! Sharp edges, sharp corners and thin sheet metal parts may cause cuts or grazes.
Page 5
Assembly Assembly Earthing connections KSFS-...-Ex General information Ducted particulate filters of Type KSFS are con- nected directly to the duct via flanges using optional spigots. The unit weight must be compensated by on-site measures (suspensions or similar). Fix the unit only to load-bearing structures. ...
Connecting the ductwork Connecting the ductwork Filters, inserting Type KSFS ducted particulate air filters are supplied Note: The insertion of the filter is described using as follows: the main filter as an example; the insertion of the prefilter is identical. with flanges ...
Page 7
Commissioning Set the filter (Fig. 5/1) with the seal (Fig. 5/2) facing upwards into the clamping frame and push it in up to the rear travel stop. Fig. 4: Releasing the clamping frame Release the clamping frame by turning the operating lever (Fig.
Page 8
Commissioning Fig. 7: Attaching the maintenance sack Put the maintenance sack (Fig. 7/1) over the service board (Fig. 7/2) and fasten it in the first groove with the clamping ring (Fig. 7/3). Roll up the maintenance sack and place it in front of the particulate filter element.
Maintenance Maintenance Changing the filter Personnel: Maintenance applies mainly to the filter element. Check the filter regularly and replace it, if neces- Properly trained person sary. Protective equipment: The service life of a filter depends mainly on how Industrial safety helmet ...
Page 10
Maintenance Fig. 9: Releasing the clamping frame Fig. 8: Opening the cover Release the clamping frame by turning the Unscrew the clamping screws (Fig. 8/1) on operating lever (Fig. 9/1) clockwise. the cover using the star grip. Remove the cover from the casing by both handles (Fig.
Page 11
Maintenance Fig. 11: Filters, inserting NOTICE! Fig. 12: Pressing the filter on Do not damage the filter. Press the filter seal against the sealing integrity test facility using the clamping Handle filter elements with care and hold frame. Then turn the operating lever them only by the edges.
Page 12
Maintenance Only required for low-contamination filter changes: Fig. 14: Closing the casing Place the cover on the filter casing, and Fig. 13: Attaching the maintenance sack tighten the star knob screws (Fig. 14/1) Put the maintenance sack (Fig. 13/1) over hand-tight.
Page 13
Maintenance Handling of the maintenance sack (low-contami- nation filter change) EXPLOSION HAZARD! KSFS-...-Ex: Use the welding device only if there EXPLOSION HAZARD! is no potentially explosive atmosphere. Switch off the air conditioning system before changing the filter, if necessary rinse with fresh air beforehand.
Page 14
Maintenance EXPLOSION HAZARD! KSFS-...-Ex: Mount the earthing cable from the filter chamber cover (Fig. 2/2). Sealing integrity test Remove the old maintenance sack from groove 1 and place it behind the new filter. Pushing the new filter into the casing Press the filter on, Fig.
Page 15
MD-DPC, using the pressure measurement points only original TROX filters. (Fig. 16/2 and 4) on the duct. Original TROX filters carry a sticker on the frame Alternatively, filter monitoring is also possible with with both the use before date and information on close-meshed, temporary differential pressure how to order replacements.
Page 16
Maintenance Cleaning the filter casing Personnel: Properly trained person Protective equipment: Light respiratory protection It is usually not possible to regularly clean and dis- infect the ductwork between the second filter stage and the filter casing, and neither is it required for hygienic reasons.