Summary of Contents for Sanken SWH Series

  • Page 1 Operation Manual SWH Series - Switch Mode Power Supply No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com. Downloaded from...
  • Page 2: Table Of Contents

    Safety Precautions 3 - 5 Appearance and Meaning of Safety Warnings Hazard and Caution Safety Warnings Other Precautions Introduction to SWH Series External Dimensions Model Number Description Input and Output Terminals, Connections and Pin Assignments Functional Description (5) 9 - 11 5.1 Input Voltage Range, Harmonic Current and Inrush Current...
  • Page 3: Safety Precautions

    3. Although Sanken strives to improve the quality and the reliability of the products, please implement safety design of the devices under customers' responsibility not to endanger human life, health and property due to malfunction and/or failures of the products when using.
  • Page 4: Appearance And Meaning Of Safety Warnings

    • Please contact the vendor from which the product was purchased and / or Sanken • In case of fire, use a fire extinguisher of a powder / ABC type approved for the use on electrical fires Note: Never use water No.
  • Page 5: Other Precautions

    Be sure not to use the products under such conditions. Although Sanken strives to improve the quality and the reliability of the products, the customer and user are responsible to be apply safe design of their equipment before using the products.
  • Page 6: Introduction To Swh Series

    Introduction to SWH Series General Description The SWH employs Sanken’s proprietary LLC type resonant-mode and silicon carbide technology. The PSU is single output, providing 115% peak power for 10s whilst occupying a market leading position for efficiency Features and Benefits •...
  • Page 7: External Dimensions

    4. Recommended fastening torque for the output terminals: 1.4N・m max Model Number Description [AAA] [NNN] –[NN] Nominal total rated output voltage (24V or 48V) Nominal total rated output wattage (650W) Series identifier, for example, SWH for SWH series No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en...
  • Page 8: Input And Output Terminals, Connections And Pin Assignments

    Remote ON/OFF input # Be sure not to short circuit between AUX and GND CN601 Conforming housing Housing PHDR-08VS SPHD-001T-PO.5 Contact SPHD-002T-PO.5 No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com.
  • Page 9: Functional Description

    When OVP is activated, it will shut down the input and then the output will recover by reapplying input after 1 min The recovery time may vary depending on input voltage and etc. when operating No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com.
  • Page 10: Output Voltage Variation

    (PC’s forward drop = 1V) Use twisted or shielded wires to prevent noise induction The remote ON/OFF control circuit is insulated from the input, output and FG No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com. Arrow.com. Arrow.com.
  • Page 11: Dynamic Load

    5.7 Others Increase voltage gradually when conducting withstand voltage test at incoming inspection and etc. Upon completion of test, decrease voltage gradually when voltage is shut down No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com. Arrow.com. Arrow.com.
  • Page 12: Mounting, Derating And Lifetime

    Be sure to secure more than 50mm space at input/output side and fan side when installing as described below If cooling is not made effectively, output may be stopped. Air flow 50mm min 50mm min No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com. Arrow.com. Arrow.com. Arrow.com.
  • Page 13: Derating

    100% Less than Ta=50℃ 10 years 10 years Less than Ta=60℃ 7 years 7 years * Assumption: Routine inspection of the fan is conducted. No. PAN40009-001E-01 SANKEN ELECTRIC CO., LTD December 2016 http://www.sanken-ele.co.jp/en/ Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com.
  • Page 14: Specification And Standards

    One hour in each of three directions Shock Resistance 196.1m/s² (20G) Installation Conditions Derating may be required due to mounting orientation Continued on next page No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com.
  • Page 15 11. When applying peak current, be sure not to exceed the maximum peak current. When the output voltage exceeding the rated output voltage, the maximum peak current is limited by the peak output power. No. PAN40009-001E-01 December 2016 SANKEN ELECTRIC CO., LTD http:// www.sanken-ele.co.jp/en Arrow.com.