Insert Installations - Breckwell Tradition P24FSA Owner's Manual

Tradition series
Hide thumbs Also See for Tradition P24FSA:
Table of Contents

Advertisement

INSTALLATION
11

INSERT INSTALLATIONS

Insert installations must be vented with 3" or 4" pipe.
Pipe may be single wall stainless steel flexible pipe.
Vent may terminate within chimney beyond a blanking
plate or extend to the chimney top. See
"COMBUSTION AIR SUPPLY" for outside air access
information.
The fireplace and chimney should be cleaned
thoroughly before starting the installation. We suggest
painting the interior of particularly old and dirty
fireplaces to seal any odors. In zero-clearance
fireplace installations, when the fireplace opening is
above the floor or raised hearth, the adjustable
"Breckwell P24 Z-C Skirt" (part # A-ZC-SKRT), or
"Breckwell P24 Z-C Legs" (part #A-S-ZCLEGS), can
be used to bridge the gap between the hearth and
stove bottom. (Refer to figure 13)
A.
ASSEMBLING THE FLASHING SET
Follow the instructions packaged with the P24
Flashing set part C-P24-MEDFL-C or C-P24-LGFL-C.
(Refer to Figure 14)
FIGURE 13
FIGURE 14