Receiver Section (Refer to the Table 1 on page 22 for the frequencies which will apply in the adjustment mode.)
Item
Condition
1. Band Pass
1) Adj item: [BPL.]
Tuning
Adjust: [
[Low]
2) Spectrum analyzer setting
Center-f: 400.050MHz
Span: 200MHz
RBW: 100kHz
VBW: 100kHz
ATT: 5dB
3) Tracking generator output
: –30dBm
[Center]
4) Adj item: [BPC.]
Adjust: [
5) Spectrum analyzer setting
Center-f: 435.050MHz
Span: 200MHz
RBW: 100kHz
VBW: 100kHz
ATT: 5dB
6) Tracking generator output
: –30dBm
[High]
7) Adj item: [BPH.]
Adjust: [
8) Spectrum analyzer setting
Center-f: 469.950MHz
Span: 200MHz
RBW: 100kHz
VBW: 100kHz
ATT: 5dB
9) Tracking generator output
: –30dBm
2. Squelch
1) Adj item: [SQTL.]
Tight
Adjust: [
2) SSG output
• Wide
: –117dBm (0.32µV)
[Low]
SSG MOD: 1kHz
SSG DEV: 3kHz
[Center]
3) Adj item: [SQTC.]
Adjust: [
4) SSG output
: –117dBm (0.32µV)
[High]
5) Adj item: [SQTH.]
Adjust: [
6) SSG output
: –117dBm (0.32µV)
• Narrow
7) Adj item: [SQTC.]
[Center]
("N" icon appear)
Adjust: [
8) SSG output
: –117dBm (0.32µV)
SSG MOD: 1kHz
SSG DEV: 1.5kHz
ADJUSTMENT
Measurement
Test-
Unit
equipment
Spectrum
Rear
]
analyzer
panel
Tracking
TX-RX
generator
(A/2)
]
]
SSG
Rear
]
Oscilloscope
panel
AF VM
Distortion
meter
]
]
]
Adjustment
Terminal
Unit
Parts
ANT
Front
Tuning
By turning the Tun-
panel
control
ing control, adjust
the band-pass fi lter
BPF
waveform as shown.
ANT
Write
EXT.
SP
TM-481A
Specifi cations / Remarks
Method
Refer to Fig. 1 (page 23).
Refer to Fig. 2 (page 23).
Refer to Fig. 3 (page 23).
27