Performance - BOWMAN 2-25-3737-4 Installation, Operation, Maintenance Manual

Exhaust gas heat exchangers
Table of Contents

Advertisement

7 Performance

Typical examples of exhaust gas heat exchanger performance. The figures below are a general
guide only and are not based on any particular natural gas engine. They assume an air/fuel
ratio of 10.23 : 1 by volume, a fuel consumption of 0.34m
15°C) and an exhaust gas temperature of 600°C and a water temperature of 80°C.
Figures are based on new and clean conditions.
Typical
Type
Engine Power
kW
2-25-3737-4
2-32-3737-5
3-32-3738-5
3-40-3738-6
3-60-3738-8
4-32-3739-5
4-40-3739-6
4-60-3739-8
5-32-3740-5
5-40-3739-6
5-60-3740-8
6-32-3741-5
140
6-40-3741-6
140
6-60-3741-8
140
8-32-3742-5
250
8-40-3742-6
250
8-60-3742-8
250
10-32-3744-5
400
10-40-3743-6
400
10-60-3743-8
400
12-32-3744-5
600
12-40-3744-6
600
12-60-3744-8
600
15-40-5745-6
950
15-60-5745-8
950
E.J. Bowman (Birmingham) Ltd, reserve the right to change specification and technical alteration without prior notice.
Iss A 05/14
Exhaust Gas Flow
kg/min
16
1.2
16
1.2
32
2.4
32
2.4
32
2.4
60
4.5
60
4.5
60
4.5
90
6.7
60
4.5
90
6.7
10.5
10.5
10.5
18.7
18.7
18.7
30
30
30
45
45
45
70
70
3
/kWh (measured at 1.013 bar and
Exhaust Gas
Heat Recovery
Outlet Temp
kW
°C
210
9.5
170
11.5
210
170
120
210
170
120
210
170
120
210
170
120
101
210
147
170
161
120
181
210
236
170
256
120
288
210
353
170
388
120
425
170
604
120
670
9
Exhaust Gas
Pressure Drop
kPa
1.6
1.8
19
1.5
21
1.7
23
2.2
35
1.3
39
1.4
43
1.8
53
1.2
39
1.4
65
1.8
82
1.3
90
1.4
1.9
1.3
1.4
1.8
1.3
1.4
1.8
1.3
1.5
1.9
1.4
1.9

Advertisement

Table of Contents
loading

Table of Contents