3.
OPERATION.
3.1.
ZERO SETTING.
Prior to operation, perform a zero setting. To do this place the gauge foot (fig1.5.) on a flat
surface. Press the probe (fig1.1.) down until it is level with the foot then press the 'ZERO'
button (fig1.7.); the gauge has been set to zero when the LCD displays '0.00'. Note: After
zero setting, the gauge retains this setting until the 'ZERO' button is pressed again or the
battery is removed.
3.2.
PRODUCT USAGE.
Switch on the gauge by pressing the ON/OFF button (fig.1.6.). Place the gauge foot across
the tyre tread with the probe tip over the tyre groove. Press the probe down until it stops
moving then read the display. The pressure exerted by the tip of the measuring probe must
be uniform and constant to ensure correct and stable readings. Do not press too hard or
incorrect results will be recorded.
4.
MAINTENANCE.
4.1.
BATTERY INSTALLATION/REPLACEMENT (fig.2)
NOTE! The battery should last for one year of
continuous use. If the display is blank or the digits are
flashing the battery voltage is too low, replace the
battery with a new SR44 battery. If the digits do not
change when buttons are pressed or probe is moved,
remove the battery for 1 minute to reset the unit. The
battery should be removed if the gauge is not to be
used for a long period of time.
4.1.1. Remove battery cover by sliding backwards and lifting
off.
4.1.2. Remove exhausted battery and fit replacement with +ve
side uppermost. Place the battery into the recess and
press into place. Slide the cover back and click home.
4.1.3. Dispose of old battery in a safe and approved manner.
Do not burn.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
Do not incinerate battery as it may explode when exposed to fire.
Do not attempt to open battery.
Contact your local solid waste authority for recycling information.
Dispose of batteries according to local authority guidelines.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasers of products containing batteries (as defined within these regulations), that they are registered with
Valpak's registered compliance scheme. Jack Sealey Ltd's Batteries Producer Registration Number (BPRN) is
BPRN00705
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and
component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave
your full name, address and postcode.
© Jack Sealey Limited
Environmental Protection.
Battery Removal.
See Section 4.1 for battery removal.
Sole UK Distributor,
Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,IP32 7AR
Original Language Version
01284 757500
01284 703534
fig.2
www.sealey.co.uk
Web
sales@sealey.co.uk
email
VS0565
ISSUE No:1 25/03/13

Advertisement

loading