hengel Bi-Tronic Control User Instructions

Hide thumbs Also See for Bi-Tronic Control:

Advertisement

User instructions
Bi-Tronic Control - Retarder proving
To be conserved by the user
Hengel Industrie
ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE
Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09
Email: infos@hengel.com
Website: www.hengel.com
Notice-EN-BITRONIC-ST-F-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bi-Tronic Control and is the answer not in the manual?

Questions and answers

Darren
February 3, 2025

Hengel wiring diagram

Summary of Contents for hengel Bi-Tronic Control

  • Page 1 User instructions Bi-Tronic Control - Retarder proving To be conserved by the user Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 2 28/03/19 Initial document creation YM / SG Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 3: Table Of Contents

    1 - GENERAL INTRODUCTION ............ 4 Interface areas ................... 4 Key’s List and LEDs ................5 2 - GETTING STARTED WITH THE BI-TRONIC CONTROL INTERFACE 6 Getting started ..................6 Setting the clock ................. 6 3 - EXAMPLE OF USE ..............7 Operating mode ..................
  • Page 4: General Introduction

    1 - GENERAL INTRODUCTION The company HENGEL thanks you for your trust. The interface BI-TRONIC CONTROL is simple and intuitive. It has a seven-segment display. It has the following form: Interface areas Retarder proving cycle zone Operating state Display Display of the temperature...
  • Page 5: Key's List And Leds

    Green LED: cycle during fermentation Validate / Save changes Orange LED blinking: setting the proving time Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 6: Getting Started With The Bi-Tronic Control Interface

    2 - GETTING STARTED WITH THE BI-TRONIC CONTROL INTERFACE Getting started When first switching on the device, the device is ready for operation. To turn it on, press the “On / Off” key for 1 second. The display lights up and indicates the time.
  • Page 7: Example Of Use

    Time Proving cycle ~ 30 mn time set point Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 8: Direct Mode

    It is then possible to stop the machine. Press the “On / Off” button for 5 seconds. The display shows “Off”. Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 9: Cycle Mode

    This is the goal of the first phase of the cycle. This phase lasts 20 minutes. It is therefore necessary to start the fermentation cycle approximately 30 minutes before the products are introduced into the chamber. Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 10 Then, the proving time LED blinks in orange. Adjust the time using the “Plus” and “Minus” buttons, then “Validate”. 5:00 Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 11 3 seconds to stop the cycle. It is then possible to stop the machine. Press the “On / Off” button for 5 seconds. The display shows “Off”. Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 12: Faults And Parameters

    Products are no longer suitable for consumption.. Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com Notice-EN-BITRONIC-ST-F-1 Tél : +33 (0)4 77 23 40 00 - Fax : +33 (0)4 77 23 40 09...
  • Page 13: Stopping The Control Interface

    Attention, when the display is in standby, some relays of the electronic card of the device are always under tension. In case of intervention, switch off the power supply. Hengel Industrie ZA, Les Berges du Rhins - 42120 PARIGNY - FRANCE Email: infos@hengel.com...

Table of Contents

Save PDF