6 Technical specifications

6.1 Compliance with standards:
Compliant with the EN 61010-1 standards, installation category II,
pollution degree 2.
6.2 Supply voltage:
115/230 V, 50 Hz switchable by a voltage selector below the device.
Primary protection fuse
(F 250 mA, 250 V, CEI 127 compliant) placed in the device, not
accessible to the user.
6.3 Power consumed:
20 VA
6.4 Frequencies delivered:
Frequency range 1 Hz to 110 KHz in 5 ranges:
Range no. 1 (by pressing simultaneously the buttons x10 and x100):
1 to 11 Hz
Range no. 2 (button x10): 10 to 110 Hz
Range no. 3 (button x100): 100 to 1100 Hz
Range no. 4 (button xl K): 1 to 11 KHz
Range no. 5 (button x10 K): 10 to 110 KHz
Linear characteristic better than 5 %.
Display of the frequency by a button on the 10 turns potentiometer
providing an accuracy greater than 5 %.
6.5 Generator output
Connection: 2 4 mm sockets
Impedance 50 Ω
Wave shapes: sinusoidal, triangular and rectangular symmetrical.
Open circuit voltage: 0 to 20 VDC, continuously adjustable.
DC offset voltage: 0 to ± 5 V continuously adjustable.
Attenuation (by push-button) 1 - 1/10 - 1/100.
Harmonic rate ≅ 1 %.
6.6 Associated LF amplifier (GF 3):
Can operate independently from the functions generator.
Connection: 4 mm sockets
Adjustable output level.