3.
PREPARING WRENCH FOR USE
3.1.
Air Supply
3.1.1. Ensure wrench air valve (or trigger) is in the "off" position before connecting to the air supply.
3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.
3.1.3. F WARNING! Ensure the air supply is clean and does not exceed 90 psi while operating the
wrench. Too high an air pressure and unclean air will shorten the product life due to excessive
wear, and may be dangerous causing damage and/or personal injury.
3.1.4. Drain the air tank daily. Water in the air line will damage the wrench.
3.1.5. Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig 1.
3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8
metres). The minimum hose diameter should be 1/4” I.D. and fittings must have the same
inside dimensions.
3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain
that all connections are secure.
3.2. Couplings.
Vibration may cause failure if a quick change coupling is connected directly to the wrench. To
overcome this, connect a leader hose to the wrench. A quick change coupling may then be used to
connect the leader hose to the air line recoil hose. See fig 1 & 2.
fig 1
4.
OPERATING INSTRUCTIONS
F
WARNING! Ensure you read, understand and apply safety instructions before use.
p
4.1.
Only use impact sockets which are specifically designed for use with an impact wrench.
4.2.
Connect the wrench to the air hose as in chapter 3.
4.3.
Place the socket over the subject nut and depress the trigger to operate the wrench.
4.4.
To change direction push the button at the top of the handle. Direction of “R” for reverse and
“F” for forward.
4.5.
The flow of air may be regulated by adjusting flow valve at the base of the handle.
DO NOT use any additional force upon the wrench in order to remove a nut.
DO NOT allow wrench to free run for an extended period of time as this will shorten its life.
fig 2
5.
MAINTENANCE
F
WARNING! Disconnect wrench from air supply before changing accessories, servicing or
performing maintenance. Replace or repair damaged parts. Use genuine parts only. Non-
authorised parts may be dangerous and will invalidate the warranty.
5.1.
Lubricate the air wrench daily with a few drops of Sealey air tool oil dripped into the air inlet.
5.2.
Check and top up the gearbox by removing the set screw (item 14 on the parts diagram).
5.3.
Clean the wrench after use. DO NOT use worn, or damaged sockets.
5.4.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or
type of hose connectors. To remedy check the air supply and follow instructions in
chapter 3.
b) Grit or gum deposits in the wrench may also reduce performance. Remove the strainer,
clean it and flush the wrench out with gum solvent oil or an equal mixture of SAE No 10 oil
and paraffin.
Allow to dry before use.
5.5.
For a full service contact your local Sealey service agent.
5.6.
When not in use, disconnect from air supply, clean wrench and store in a safe, dry,
childproof location.
Declaration of Conformity
We, the sole importer into the UK, declare that the product listed here is in conformity with the
following EEC standards and directives. The construction file for this product is held by the
Manufacturer and may be inspected, by a national authority, upon request to Jack Sealey Ltd.
Air Impact Wrench
Model: SA59.V2
98/37/EC Machinery Directive
93/68/EEC Marking Directive
Signed by Mark Sweetman
26th June 2002
For Jack Sealey Ltd. Sole importer into the UK
of Sealey Power Tools.
SA59.V2 - 1 - 260602