Summary of Contents for Eagle Eye LB-60-70

  • Page 1 LB-60-70 LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS Eagle Eye Power Solutions, LLC. 4031 W Kiehnau Ave Milwaukee, WI 53209 Eagle Eye Power Solutions, LLC.
  • Page 2 TEMPORARY USE ONLY. THE LOAD RESISTORS ARE ENERGIZED WHEN THE RATE SWITCH IS OFF; THEREFORE DO NOT INSERT ANY OBJECTS IN THE GRILL ASSEMBLY. DO NOT BLOCK THE AIR FLOW OR USE IF THE AIR FLOW IS REVERSED. Eagle Eye Power Solutions, LLC.
  • Page 3: Table Of Contents

    MANUAL FOR LB-60-70 LOAD BANK TABLE OF CONTENTS SUBJECT SECTION PAGE DESCRIPTION PURPOSE OF LOAD BANK 1 - 1 RATING OF LOAD BANK 1 - 2 LOAD BANK DESCRIPTION FIGURE 1 - 1 1 - 3 CONTROL PANEL LAYOUT FIGURE 1 - 2...
  • Page 4: Description

    1-2 RATING OF LOAD BANK: The LB-60-70 is rated at 70 KW full load with all four load steps turned on and the rotary rate switch set to 5KW. The load steps are 5KW, 10KW, 20KW and 30KW plus a rotary rate switch with loads of 1-5KW.
  • Page 5 Eagle Eye Power Solutions, LLC.
  • Page 6: Control Description

    METER TEST JACKS - This provides a place to connect an external meter. There is a test jack for each cable pin. POWER RECEPTACLE - The power cable from the equipment to be tested is plugged into the load bank through the receptacle. Eagle Eye Power Solutions, LLC.
  • Page 7: Operation

    2-5 SHUTTING DOWN - After turning the rate off, allow the load bank to cool down before turning the power unit off. Turn the power unit off and disconnect the power cable plug. Eagle Eye Power Solutions, LLC.
  • Page 8: Testing 240Vac Single Phase

    2-5 SHUTTING DOWN - After turning the rate off, allow the load bank to cool down before turning the power unit off. Turn the power unit off and disconnect the power cable plug. Eagle Eye Power Solutions, LLC.
  • Page 9: Testing 208Vac Three Phase

    2-5 SHUTTING DOWN - After turning the rate off, allow the load bank to cool down before turning the power unit off. Turn the power unit off and disconnect the power cable plug. Eagle Eye Power Solutions, LLC.
  • Page 10: Parts Information

    Parts should be ordered from the address below giving the machine model number, part number and the description. Contact EEPS Eagle Eye Power Solutions, LLC. 4031 W Kiehnau Ave Milwaukee WI, 53209 TEL: 1-877-805 EEPS (3377) FAX: 1-414-962-3660 www.eepowersolutions.com...
  • Page 11 Eagle Eye Power Solutions, LLC.
  • Page 12 ROTARY SWITCH 3 POSITION 1 POLE LT-10 115VAC AMBER LIGHT SW-31 ROTARY SWITCH 10 POSITION 3 POLE SW-22 TOGGLE SWITCH DPST SW-21 TOGGLE SWITCH SPST TP-10 TEST PIN SB-12 SB CONNECTOR 2PIN-YELLOW SB-13 SB CONNECTOR 2PIN-BLUE LT-25 250VAC RED LIGHT Eagle Eye Power Solutions, LLC.
  • Page 13 Eagle Eye Power Solutions, LLC.
  • Page 14 ZENER DIODE 10V 5W RC-56 RESISTOR 5.6KΩ 5W ZN-12 ZENER DIODE 120V 5W RY-20F RELAY 24VDC, 2PDT 3A FLANGE RC-09 RESISTOR 10KΩ .5W ADJ ZN-24 ZENER DIODE 24V 5W TM-13 TERMINAL STRIP GL-20 RESISTOR GRILL Eagle Eye Power Solutions, LLC.
  • Page 15 Eagle Eye Power Solutions, LLC.
  • Page 16 NUMBER VENDOR NO. USED FP-57 ALUM. FAN PANEL TM-20 8 POSITION TERMINAL STRIP V-BEAU PRODUCTS (78008) SW-12 TILT SWITCH GL-10 GRILL CHROME FN-25 24 VDC FAN TS-15 THERMAL SWITCH PS-30 POWER SUPPLY 28- 33VDC 400W Eagle Eye Power Solutions, LLC.
  • Page 17 To remove the fan panel, remove the screws around the outer edge. The meters can be removed and replaced from the front panel. The fan grills should be kept free of any trash. Do not place any objects in the fan or resistor grill. Eagle Eye Power Solutions, LLC.
  • Page 18 Rivet the new fan back to the fan panel and install the fan guard. Install the wires back on the terminal strip and place the fan panel back on the load bank. Make sure that the wires are on the proper terminals. Eagle Eye Power Solutions, LLC.
  • Page 19 Eagle Eye Power Solutions, LLC.
  • Page 20 Eagle Eye Power Solutions, LLC.
  • Page 21 Eagle Eye Power Solutions, LLC.
  • Page 22 Contact EEPS Eagle Eye Power Solutions, LLC. 4031 W Kiehnau Ave. Milwaukee WI, 53209 TEL: 1-877-805 EEPS (3377) FAX: 1-414-962-3660 www.eepowersolutions.com info@eepowersolutions.com Eagle Eye Power Solutions, LLC.