1 Safety Instructions This product is a combination of an electronic controller and the respective accessories. It has been assembled and tested according to the safety measures applied to electronic devices in the EC. It has been cleared by the quality department within the factory. To preserve status and guarantee operation safety, the following instructions must be observed.
4 Installation This controller includes a front display, a central control key and a side button. The controller must be set up vertically, on a plane surface, keeping at least 15cm from the wall and from other components to ensure proper ventilation. Make sure that all the hydraulic circuits are shut and that the power supply is isolated before beginning installation.
Fig 4 – Clamp Saddle 4.2 Electrical Installation 4.2.1 Instalattion of Electrolysis Cell The connection to the electrolysis cell is done through two conductors of 6 to 10mm2 (depending on the cell power) and two conductors of 0.75mm2, both supplied with the system. One of the 0.75mm2 conductors has one M3 terminal, the remaining conductors have two M6 terminals which must be connected to the corresponding terminals in the cell (see Figure 5).
Command buttons Switch 0 – OFF I – ON II - COVER Figure 6 – Command Buttons This device only has two buttons: Main Control Button and Side Switch with positions 0, I, II (see figure 6). The display allows you to view the system status and obtain information about the active alarms. Chlorine Production Chlorine Concentration Salt Concentration...
It is recommended that electrolysis is not frequently activated and deactivated because it reduces cell life. Bright Blue is not responsible for errors or faults of the external equipment that have a direct effect on the quality and disinfection of the pool water.
In case the cover is manual, the user must set the equipment side switch to the position "II" whenever the pool is covered. 5.6 Disinfection Recommendations It is advisable to disinfect it overnight. In fact, ultraviolet radiation acts on the chlorine produced by the electrolysis cell, catalyzing salt regeneration (which is why salt consumption is insignificant).
Figure 10 - Current Adjustment 0A To re-calibrate briefly press the Command Button and the following information will be displayed: Figura 11 – Ajuste de corrente STD (Standard) The STD current must equal the production capacity of the installed cell (8G = 8A; 10G = 10A, etc ...).
6.3 Setting ORP Limits This menu allows you to configure the ORP (HIGH) and minimum (LOW) limits to determine the correct concentration of chlorine in the water. The value of ORP is not the same from pool to pool being dependent on factors external to the equipment, so the correct limits should be checked case by case in the pool where the equipment is installed.
characteristics of the water, namely its calcium hardness. The higher the water hardness, the lower the defined range should be, to ensure that no encrustation occurs on the titanium plates. The equipment is factory set at 6H and can be changed to a range between 3H and 8H. IMPORTANT: the shorter the inversion time the shorter the lifetime of the electrolysis cell.
7.3 Alarm 2B - Low Salt This alarm (ALARM 2B) is released when the electrolysis reaches the minimum threshold of 69%. The system continues to function, but the production of electrolysis is reduced and may be insufficient for good disinfection of the water. This alarm is indicative that the concentration of salt in the pool is below the recommended minimum, or that there is a malfunction in the electrolysis cell.
PLUMA: 2 years or 10.500h of operation for the electrolysis cell; 2 years for the electronic equipment. The Bright Blue Ltd reserves the right to change the terms and conditions of this warranty, without notice, even after the invoice date of purchase, applying the terms and conditions in force 9.3 Warranty Exclusions...
Page 15
In this case, Bright Blue or its representative will send the customer an estimate of the diagnosis, repair and transportation costs. The customer can order the return of the goods, without repair, in which case Bright Blue will issue an invoice of the diagnosis fee and dispatch costs.