  • Page 1 AquaMax User Manual MSCT 1 shower change trolley – Operation and maintenance manual Mobile Shower / Changing Trolley R9464717000-R844717304 R9464717000-R844717302 R9464721000-R844721304 R9464721000-R844721302 MAX-Ability, Inc. info@max-ability.com 800 577-1555...
  • Page 2 Find out more about this product by clicking here. Or go to https://max-ability.com/product/pressalit-shower-trolley/ The guarantee covers faults or defects in material or manufacture within a period of 5 years. Products are subject to minor technical modifications and design deviations. E.&O.E.
  • Page 3 R9464717000 R9464721000 max-ability.com 800.577.1555 info@max-ability.com...
  • Page 4 R844721 R844717 R844521 info@max-ability.com 800.577.1555...
  • Page 5 6 1 ¹ ⁄ 9 ³ ⁄ 6 ¹ ⁄ 7 0 ¹ ⁄ ⁵ ⁄ ⁹ ⁄ 8 2 ¹ ¹ ⁄ 6 1 ¹ ⁄ 9 ³ ⁄ 6 ¹ ⁄ 8 6 ¹ ⁄ ⁵ ⁄ max-ability.com 800.577.1555 info@max-ability.com...
  • Page 6: Table Of Contents

    Disposal and recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 7: Symbols Used In This Manual

    NOTICE NOTICE is used to address practices not related to personal safety . Hand injury warning Head injury warning Electricity or potentially Feet injury warning dangerous voltage . Do not leave the patient Compatible products unattended . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 8: General Safety

    Assembly instruction . • Pressalit cannot be held liable if the product is used in any way which differs from that described in the guide . • We reserve the right to amend this manual without prior notice . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 9: Product Label

    Product label ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ① ⑱ RZZZZYYYXXX-X XX-XX Hz XX W YYYY-MM-DD XXX V IPXX ② ⑲ xxx kg xxx kg xxx lbs xxx lbs ③ ⑳ xxx kg xxx lbs YY-MM-DD ④ ⑤ Pressalit A/S, Pressalitvej 1 DK-8680 Ry +45 8788 8777, www.pressalit.com ⑫...
  • Page 10 Council Directive 2011/65/EC on RoHS . This product is CE-marked in accordance with the European Medical Device Directive 93/42/EEC, including amendments incorporated in Directive 2007/47/EEC . A declaration of conformity can be found at www pressalit com . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 11: Intended Use

    The materials in contact with the skin of the patient or the user during the changing procedure, have been tested for their content of harmful substances according to ISO 10993 Biocompatibility, and are therefore considered suitable for this purpose . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 12: Operating Instructions

    . wheels . WARNING Always ensure that the brakes are locked when transferring a patient to and from the shower change trolley . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 13: Moving

    Use the cut-out grips on the side supports when moving the shower change trolley . Push straight ahead in the desired direction . Do not twist or turn the side support . Do not leave the patient unattended . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 14: Side Supports

    . down . WARNING When the trolley is in use, make sure that all side supports are erect and in locked position to protect the patient from falling out of the unit . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 15: Height Adjustment

    Height adjustment The shower change trolley can be adjusted 400 mm / 153/4" up and down . Max user weight: 200 kg / 440 lbs Max load: 250 kg / 550 lbs The height adjustment is controlled by the wired remote control unit . Press and hold the Up button to raise the unit .
  • Page 16: Tilt Function

    Press and hold the up button and the down button simultaneously . The columns will move down after a few seconds while a beep tone is heard . Keep holding both buttons until the beep tone disappears . The lifting columns are now reset . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 17: Charging The Battery

    The battery can height adjust the shower change trolley up to 30 times when fully charged . Release the lock to remove the battery for charging . Reattach the battery after charging before placing the patient on the shower change trolley . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 18 Please note that there is no audio signal to indicate the standby mode or to indicate exit of standby mode . If there is still no power after exit of standby mode, the battery needs to be charged . The battery must be recharged every 6 months . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 19: Accessories

    • Check for damages on the mattress on a regular basis . This will prevent infection of the mattress . • Use gloves while handling the waste hose for the mattress . It might have contact to human waste . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 20 Attach one key ring of the chain to the plug . Make a loop around one of the footboard handles with the other ring . IMPORTANT Do not move the trolley when there is water in the shower mattress . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 21: Head Rest

    . A list of suitable cleaning agents/disinfectants tested by Pressalit can be found on www .pressalit .com IMPORTANT Check for damages on the head rest on a regular basis . This will prevent infection of the head rest . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 22: Cleaning

    • For surface disinfection, chlorine-based disinfectants may be used according to the product specification and safety precautions for these products . CAUTION Do not perform any type of cleaning or disinfection of the shower change trolley while the patient is lying on it . max-ability.com 800.577.1555 info@max-ability.com...
  • Page 23: Electromagnetic Compatibility

    . See "Resetting" . Electromagnetic emissions Test standard Test level / details Test results 60601-1-2 ch . 7 .1 .7 - 30MHz – 1GHz Passed CISPR 14 max-ability.com 800.577.1555 info@max-ability.com...
  • Page 24: Technical Data

    550 – 950 mm (215/8 - 373/8) Tilt degree Battery capacity 2,25Ah Battery weight 1 kg (2 .2 lbs) Battery charging time 3-4h Expected service life of the shower change trolley is 10 years . Product label placement ①. max-ability.com 800.577.1555 info@max-ability.com...
  • Page 25: Trouble-Shooting

    In most instances the affected parts are replaced, not repaired. Parts damaged due to improper assembly, installation, or procedure; lack of recommended maintenance including cleaning; or lost after delivery cannot be included in this warranty. max-ability.com 800.577.1555 info@max-ability.com...
  • Page 26: Storage And Transportation

    . Electronics The electronic components should be collected separately and returned to the designated recycling service . Batteries Disposal of the battery must be in accordance with local regulations . max-ability.com 800.577.1555 info@max-ability.com...