Specifications - Greenlee HFC30 Instruction Manual

Flow control valve
Table of Contents

Advertisement

Available languages

Available languages

Specifications

Flow Control Valve
Hydraulic Ports:
Power Source Side:
Pressure ................... 1-1/16 – 12 SAE O-Ring Boss
Return ...................... 1-1/16 – 12 SAE O-Ring Boss
Tool Side:
Pressure ................. 3/4 – 16 SAE O-Ring Boss with
Return .................... 3/4 – 16 SAE O-Ring Boss with
Hydraulic Flow and Pressure:
Maximum Input Flow .....................113 l/min (30 gpm)
Maximum Input Pressure ................ 207 bar (3000 psi)
Maximum Output Flow ....................38 l/min (10 gpm)
Maximum Output Pressure ............. 148 bar (2150 psi)
Temperature Range .....-34 °C to 60 °C (-30 °F to 140 °F)
Length ..................................................... 223 mm (8.79")
Width ....................................................... 171 mm (6.72")
Height ...................................................... 128 mm (5.03")
Mass/Weight ............................................. 3.8 kg (8.3 lbs)
Noise Level (L
) ...........................................................10
WA
Do not exceed the following hydraulic power source
maximums:
• Hydraulic flow: 113 l/min (30 gpm).
• Pressure relief setting: 207 bar (3000 psi).
Failure to observe this warning can result in severe
injury or death.
Hydraulic Power Source
Type of Hydraulic System ........................ Open-Center or
Maximum Flow ...................................113 l/min (30 gpm)
Filtration ........................................... 10 Micron (Nominal)
Pressure Relief Setting ........................ 207 bar (3000 psi)
1. Maximum hydraulic fluid temperature must not
exceed 60 °C (140 °F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
2. Hydraulic flow must not exceed 113 l/min (30 gpm).
Install a flow meter in the return line to measure to
rate of hydraulic flow before using the valve.
Greenlee Tools, Inc.
HTMA Flush Face Coupling
HTMA Flush Face Coupling
Closed Center
HFC30 Flow Control Valve
Hydraulic Schematic
RESERVOIR
PUMP
POWER SOURCE
TOOL
Recommended Hydraulic Fluids
Use any non-detergent, petroleum-based hydraulic fluid
which meets these specifications or HTMA specifications:
S.U.S. @:
38 °C (100 °F) .............................................140 to 225
99 °C (210 °F) .......................................... 40 minimum
Flash Point ................................170 °C (340 °F) minimum
Pour Point ..................................-34 °C (-30 °F) minimum
5
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
FILTER
(10 MICRON)
RELIEF
COOLER
VALVE
207 bar
(3000 psi)
T
CONTROL
VALVE
FLOW METER
P
P
RELIEF
VALVE
148 bar
(2150 psi)
T
P
T

Advertisement

Table of Contents
loading

This manual is also suitable for:

49550

Table of Contents