Haussmann PG2200-3 Operator's Manual page 27

Table of Contents

Advertisement

Available languages

Available languages

DESCRIPTION, SPECIFICATIONS AND INSTRUCTIONS
Oil cock
Warning: gasoline is highly
volatile, flammable and
explosive.
Warning: Check the oil
level
before operation.
Fuel gauge
Voltmeter
ON/OFF
Alternating current (AC)
Direct current (DC)
Overload cut-out
Positive pin of direct
current/Negative pin of
direct current
240 V
Selection switch
120V~/240V~
120 V
120 V~ socket-outlet
L1,2 AC 120V~
240 V~ socket-outlet
AC 240V~
Technical data
PG2200-3
2500W GENERATOR
AC FREQUENCY(HZ):
Continuous rated power (S1):
2000 W/240 V; 2000 W/120 V~
Maximum power max (S2 5 min):
2500 W/240 V~; 2500 W/120 V~
AC OUTPUT VOLTAGE:
TRANSFER SWITCH:
RATED/MAX AC CURRENT 120V:
RATED/MAX AC CURRENT 240V:
DC OUTPUT:
SOCKETS :
ENGINE:
FORCED AIR-COOLED 4-STROKE OHV
POWER:
DISPLACEMENT(CC):
STARTING SYSTEM:
FUEL TANK CAPACITY:
OIL CAPACITY:
Operating mode S1 (continuous
operation)
The machine can be continuously operated
with the quoted power output.
Operating mode S2 (temporary
operation)
The machine may be temporarily operated
with the quoted power output. Afterwards
the machine must be stopped for a while to
prevent it from overheating.
Warning!
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in closed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run the generator in a closed, or
even partly closed area where people may
be present.
27
60HZ
120V/240V
YES
16.7/20.8 AMPS
8.3/10.42 AMPS
12V/8.3A
2*120V+1*240V
SINGLE-CYLINDER
6.5 HP / 3600 RPM
196 CC
HAND RECOIL START
3.9 GAL (15 L)
0.16 GAL (600 ML)
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

59695030