Environmental Specifications

4.1

Temperature

The temperature specifications for the Iridium Edge Pro are given in the table below.
Parameter
Operating Temperature Range
Operating Temperature Range
( with SBD using reduced duty cycle)
Storage Temperature Range
4.2

Testing Compliance

The Iridium Edge Pro has been tested to the SAE J1455 specifications (March 2017) as per the
following table.
Condition
Vibration Testing
Shock
Immersion
Testing
Humidity
Chemical Splash
Resistance
Salt Spray
Resistance
Dust and Steam
Cleaning
Low Pressure
Storage
Power Supply
Testing
5

Power and Mating Cables

Iridium Edge Pro power and mating are provided by Iridium Service Providers or Value Added
Resellers. These cables and the installation instructions will vary depending on the Service Provider
and the general market requirements include sensors and equipment that are connecting to the
Iridium Edge Pro User Manual
UM_Iridium Edge Pro_v1.1_072220
Test Reference
SAE J1555, Section 4.10
SAE J1455
SAE J1455, Section 4.3.3.2
SAE J1455, Section 4.2
SAE J1455, Section 4.4.3.2
SAE J1455, Section 4.3.3.1
SAE J1455, Section 4.5.3
SAE J1455, Section 4.9.3
SAE J1455, Section 4.13.2.2.1
Value
-40 ºC to + 70 ºC
-40 ºC to + 85 ºC
-40 ºC to + 85 ºC
Test Description
5 hours on each axis as per figures 6, 7
and 8 in SAE J1455
Drop 1 m onto concrete in 3 perpendicular
orientations. 3 drops total.
3 immersions
Cable mated during immersion
Temperature Range: -40 to 85 ºC
Relative Humidity: 90%
Number Cycles: 30
Duration of Cycle: 8 hours
Brush method with selective fluids
Duration of 96 hours
At level 4
At -40 ºC for 48 hours
Load dump,
Inductive Switching,
Burst Transients
Page 19 of 26