4. Sterilization Function ---- Free from Cross-contamination
A UVC ultraviolet ray is the one that truly has germicidal effect, and C ultraviolet of which is easily absorbed
by DNA of organisms, especially, ultraviolet ray of 253.7nm is the best. UV sterilizer is a purely physical
method of disinfection, which is characterized by simple and convenient operation, high efficiency, no
secondary pollution, easy for management and automation etc.
AEOLUS UC-1801- ICU.INCBATOR uses ultraviolet sterilizer, which is characterized by strong radiation
intensity, high stability and high transmittance to quartz glass tube. The transmittance is of ≥87% and the
radiation intensity is at 253.7-254μm and remains stable. Furthermore, high brightness mirror sterilization
reaction chamber design is adopted. Compared with similar products from abroad, the sterilization strength
increases by 18%-27%.
---- Generally, the bactericidal action of ultraviolet ray on bacteria and viruses can achieve sterilization rate
of 99%-99.9% in one to two seconds.
---- The broad-spectrum of ultraviolet sterilization is the highest, and it can efficiently kill almost all bacteria
and viruses.
---- The ultraviolet sterilizer has no secondary pollution. No chemicals will be added in ultraviolet steriliza-
tion, thus, water and its surrounding environment will not be polluted secondly. Furthermore, it will not
change any ingredients in the water.
---- The operation of ultraviolet sterilizer is safe and reliable: traditional disinfection technologies such as
chloride or ozone, the disinfectants themselves are highly toxic and flammable substances, while there is
no such potential safety hazard in ultraviolet sterilization system.
5. Medical Atomization Treatment Function---- Making the Treatment More Convenient
AEOLUS UC-1801- ICU.INCBATOR is equipped with silent medical atomization function, and biomedical
engineering research shows: when the atomized particles are about 10 microns, medicines can only
deposit in the mouth and throat, when the atomized particles are about 3-6 microns, can enter into the
bronchus, and when the atomized particles are less than 2 microns, medicines can enter into the finest
bronchus and alveoli. The atomized particles of medicine produced by AEOLUS UC-1801- ICU.INCBATOR
are 0.5-4 microns. Meanwhile, intelligent control quantity of atomization is provided for your selection, and
the maximum atomizing volume is up to 0.5ml/min. The atomization in the ICU is even, and the inhalation
effect of atomized medicines is obvious. The medical built-in atomizer is characterized by low noise, which
complies with pet ICU noise standard.
AEOLUS UC-1801- ICU.INCBATOR can also provide an external air compressor atomizer you are your
selection according to users' preferences and usage, which offers greater choice space.
6. Carbon Dioxide Concentration Monitoring Systems----A Defense Line to Guard Life
An increase in carbon dioxide concentration is accompanied by a decrease in oxygen concentration. Being
anoxic under high concentration of carbon dioxide for a long time will cause pulmonary edema, cerebral
edema, metabolic acidosis, electrolyte imbalance, shock, hypoxic encephalopathy, etc. When the carbon
dioxide concentration reaches 1000PPM above, it will cause dizziness, drowsiness and reduced resistance
to pets; when the carbon dioxide concentration reaches 2000-5000PPM, it will cause mild nausea, poor
breathing, rapid heartbeat and electrolyte imbalance to pets, and seriously affect the health of pets and their
postoperative rehabilitation; and when the carbon dioxide concentration is over 5000PPM, it will cause
severe hypoxia, coma and even death.
The ICU of AEOLUS UC-1801- ICU.INCBATOR is equipped with a precise carbon dioxide concentration
monitor, which can monitor changes in carbon dioxide concentration in the ICU. When being hypoxic state
that concentration exceeds the standard value (exceeds the set value), and cannot be reduced below the
08
set value for three minutes, It will trigger the alarm system and start the intelligent ventilation system at the
same time, being ventilated with the outside air and thus improve the air quality of ICU, which becomes the
most important life defense line for pets.
7. ICU Illumination Function----Creating Comfortable Therapeutic Environment
AEOLUS UC-1801- ICU.INCBATOR uses ten-level LED lights adjustment, which can simulate various
scenes similar to parent, forest oxygen bar, warm home, forest dawn and dusk twilight, etc., providing a
cozy and conformable therapeutic environment for pets.
8. Setting of Security Mechanism---- No Worries in Use
AEOLUS UC-1801- ICU.INCBATOR adopts intelligent alarm system, and is equipped with corresponding
fault display function, such as extreme temperature and excessive moisture alarm, lack-of-water alarm and
main components fault warning lights.
AEOLUS UC-1801- ICU.INCBATOR is equipped with intelligent switch power keys, dividing into three
controls, i.e. power-on, start and power-off. This design is energy saving and safer to use.
9. Human Oriented Structural Design ---- Reasonable Operation, Clean and Convenient
All equipment components of AEOLUS UC-1801- ICU.INCBATOR adopt integrated design. All components
are integrated in a control frame, and completely separated from the control circuit. Only by disassembling
the control rack, the whole machine can be disassembled to clean various components, including fan,
medical devices, heat sink and filter etc. The operation is extremely convenient, easy for troubleshooting,
maintenance and equipment cleaning.
AEOLUS UC-1801- ICU.INCBATOR is equipped with two medical device import Interface channels, thus
external medical equipment (such as oxygen machine) can be connected into the ICU, meanwhile, the side
access port adopts medical valve importing design, being convenient for the importing of pets injection and
infusion needles and relative sealing and fixing.
Product Operation Instructions
1. Start-up and Shutdown
a) One end of the power cord is plugged into the terminal
board at the bottom support of the right side of the
machine, and the other end into the socket of 220V/50Hz
with reliable grounding. See fig. 7.1.2.
b) The power switch is located at the batter brace of the
left side of the machine. See fig.7.1.2. It is the on/off
switch of AEOLUS UC-1801- ICU.INCBATOR. When it is
locked, all other keys are void; when it is unlocked, all
other keys are valid.
c) The lock indicator lamp is at the on/off switch. When it
is on, it means unlocked; when it is off, it means locked.
Power ON/OFF
Power Interface
Figure 7.1.2
09