CCS Technical Documentation
Measuring the RX module manually using Oscilloscope and Spectrum Analyzer
Spectrum Analyzer level values depend on the probe type and should be validated using a
known good NHL-10 sample. The levels that are given here are measured using a high fre-
quency probe.
Measuring with Oscilloscope on RXINN or RXQINN (J606 –608) and RXID or RXQD (J211 –
J212) is recommended only if RSSI reading does not provide enough information. No dedicat-
ed test points exist for RX I/Q signals, however, they can be accessed by probing on a via hole
plating.
GSM900
• Start Phoenix Service Software and establish a connection to the phone.
• Select File -> Scan Product Ctrl R.
• Wait until the phone software version is shown in the lower part of the screen.
• Select Testing -> RF controls.
• Select Band -> GSM900.
• Active unit -> RX.
• Operation mode -> Continuous.
• RX/TX channel -> 7.
• AGC -> 9.