4-wire e&m with plr and er channel unit, 4-wire e&m with plr and er channel unit
Table of Contents

Advertisement

Frequency (Hz)
1150 to 2300
1000 to 2500
800 to 2700
(n) DIAL PULSE DISTORTION: 12pps at 60 percent break,
(o) LONGITUDINAL BALANCE (REFERENCED TO –16dBm TLP):
Frequency (Hz)
200
1000
3000
(p) SINGLE FREQUENCY DISTORTION: –28dBm0 at 0 to 12kHz; –40dBm0 at1020Hz.
(q) SIGNAL-TO-DISTORTION RATIO AT 1020Hz:
Signal
0 to –30dBm0
–40dBm0
–45dBm0
(r) TLP RANGES: Transmit, –22.5 to +10dBm; receive, –22.5 to +10dBm.
(s) OPERATING ENVIRONMENT: Temperature, 32 to 122 F (0 to 50 C).
12.1.2. Electrical (Single-Ended)
(t) TYPICAL CURRENT DRAIN FROM –48Vdc:
Model
3652-62
3652-68
12.1.3. Signaling
(u) OPERATION: E&M or PLR.
12.2
Physical
See Table 5 for the physical characteristics of the 3652–62 and 3652–68.
Height
Width
Depth
Weight
Delay Distortion
60usec
90usec
120usec
dB
86 minimum
80 minimum
78 minimum
Signal-To-Distortion Ratio (dB)
35 minimum
29 minimum
25 minimum
Idle
25mA
20mA
Table 5.
Feature
2 percent.
Busy
40mA
25mA
U.S.
4.3 inches
1.36 inches
10.4 inches
9 ounces
Metric
10.9 centimeters
3.5 centimeters
26.4 centimeters
255 grams