Charles 3652-62 Manual

4-wire e&m with plr and er channel unit, 4-wire e&m with plr and er channel unit

Advertisement

Quick Links

3652-62 4-Wire E&M with PLR and ER Channel Unit
3652-68 4-Wire E&M with PLR and ER Channel Unit
CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1. 3652-62 4W E&M with PLR and ER (Issue 5) Channel Unit
2000 Charles Industries Ltd.
CLEI is a trademark of Bell Communications Research, Inc.
All rights reserved. Printed in United States of America.
The availability of features and technical specifications herein subject to change without notice.
Telecommunications Group
Complies with UL Standard 1459 Second Edition (3652-68 Only)*
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3652-62
Section 365-262-205
Fifth Printing, March 2000
PAGE
Page 1 of 17
2
3
3
5
10
11
11
14
14
15
15
16

Advertisement

Table of Contents
loading

Summary of Contents for Charles 3652-62

  • Page 1: Table Of Contents

    ..............3652–62 Figure 1. 3652–62 4W E&M with PLR and ER (Issue 5) Channel Unit 2000 Charles Industries Ltd. CLEI is a trademark of Bell Communications Research, Inc. All rights reserved. Printed in United States of America.
  • Page 2: Part 1. General

    Issue 6) 4-Wire E&M with PLR and ER (4W E&M/PLR) Channel Units. These channel units are used in the Charles Industries 360/363 D4 Digital Carrier Terminal. The 3652–62 is shown in Figure 1. Table 1 lists the 4W E&M/PLR channel units and those of the former issue which they replace.
  • Page 3: Part 2. Inspection

    Equipment Identification Charles Industries’ equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment. Each time a major engineering design change is made on the equipment, the issue number is advanced by 1 and imprinted on subsequent units manufactured.
  • Page 4 Section 365–262–205 Figure 3. Typical 4W PLR Application Figure 4. Typical Tandem FX Application Type l E&M Signaling Interface Type lll E&M Signaling Interface Type ll E&M Signaling Interface PLR Signaling Interface (Type 1 Only) Figure 5. Types l, ll, lll/PLR Signaling Interface...
  • Page 5: Part 4. Circuit Description

    CIRCUIT DESCRIPTION Refer to Figure 6 and Figure 7 for the block diagrams, as needed, while reading the following circuit description. Notes are explained in Table 2. Transmit Voice Path Voice Frequency (VF) signals applied to the T&R leads (pins 50 and 48) are routed through transformer T1 to the XMT GAIN circuit.
  • Page 6 Section 365–262–205 Open, closed screw option Factory-installed optional strap Alternate position Receptacle-type optional strap Alternate position All like-designated points are connected N.O., N.C. relay contact. Ganged switches are indicated by dashed connection line or alphabetically suffixed reference designations; numeri- PC board connector pin cal suffix denotes discrete switch within a package.
  • Page 7 Open, closed screw option Factory-installed optional strap Alternate position Receptacle-type optional strap Alternate position All like-designated points are connected N.O., N.C. relay contact. Ganged switches are indicated by dashed connection line or alphabetically suffixed reference designations; numerical PC board connector pin suffix denotes discrete switch within a package.
  • Page 8 Section 365–262–205 Table 2. Note PC mount test jacks Marking Access T&R Line, J1–A Towards channel unit T&R DROP, J1–B Towards office equipment T1&R1 Line, J2–A Towards channel unit T1&R1 Drop, J2–B Towards office equipment E&M Line, J3–A Towards channel unit E&M Drop, J3–B Towards office equipment The XMT INPUT range at T&R: –22.5dBm to +10dBm.
  • Page 9 Note 20a. For 3652–62: E-lead conditions: (Both E, E2) BUSY: Leads E & EB, E2 & EB2 shorted IDLE: Leads E & EB, E2 & EB2 open For Types I & III trunk, connect Z to Z2 (EB & EB2 grounded) For Type II trunk, connect Z to Z3 (E/E2 &...
  • Page 10: Part 5. Mounting

    Section 365–262–205 stream via the XDATA lead, indicating a busy condition on the channel circuit. An on-hook condition (open) causes a logic 0 state to be transmitted with the outgoing bit stream and indicates a channel idle condition. On the 3652–62, the M2-LEAD DETECTOR will cause a logic 1 to be transmitted on the B highway for a ground con- dition on the M2-lead, and a logic 0 to be transmitted for an open on the M2-lead.
  • Page 11: Part 6. Installer Connections

    INSTALLER CONNECTIONS Electrical connections for the channel unit are made by wire-wrapping leads onto the associated 50-pin connec- tors located on the backplane of the 360/363 D4 terminal. When installing a 3652–62/68 channel unit into a non- connectorized 360/363 D4 terminal (00-suffixed), make the required connections as shown in Table 3. On con- nectorized 360/363 D4 terminals (360–10, –11, etc.), connections are made via 25-pair female connectors (CINCH 222–22–50–023 or equivalent) to the appropriate 25-pair male connectors of the 360/363 D4 terminal.
  • Page 12 Push-On Jumper Option P1/P2/P3 (E-Lead Conditioning) and W1/W2/W3 (E2-Lead Conditioning 3652-62 Only) Trunk Processing During a Carrier Failure To condition the E-lead (M-lead for tandem mode) to go idle then busy 2.5 seconds later during an alarm condi- tion, place option P in the P1 position.
  • Page 13 Figure 8. 3652-62 and 3652-68 Option Locations Table 4. Description of Figure 8 Option Position Function/Remarks NORM Normal channel unit operation BUSY Busy out channel unit for out-of-service testing NORM Normal mode (E&M signaling) Tandem mode (PLR signaling) — Reverses the E and M leads to accommodate office...
  • Page 14: Part 8. Alignment

    Section 365–262–205 Option Position Function/Remarks Condition the E2-lead to go idle then busy after 2.5 seconds during a carrier failure (3652 (3652– Condition the E2-lead to go busy during a carrier failure 62 only) 62 only) Condition the E2-lead to go idle during a carrier failure OPEN Balanced contact closure between the 1-lead and 2-lead (3652–...
  • Page 15: Part 10. Technical Assistance

    Charles Industries, Ltd. offers a standard repair or exchange service for units either in- or out-of-warranty. With this service, units may be shipped to Charles Industries for either repair and quality testing or exchanged for a replacement unit, as determined by Charles Industries. Follow the Repair Service Procedure below to return units and to secure a repair or replacement.
  • Page 16: Part 12. Specifications

    SPECIFICATIONS 12.1 Electrical The electrical characteristics of the 3652-62 and 3652-68 are as follows: 12.1.1. Transmission (Single-Ended) (a) PERMISSIBLE MODE: 4T-4T. (b) 4-WIRE IMPEDANCE: 600 ohms. (c) LINE SIDE LEVELS: Transmit (fixed), +5.2dBm TLP; receive (fixed), +5.2dBm TLP.
  • Page 17 (r) TLP RANGES: Transmit, –22.5 to +10dBm; receive, –22.5 to +10dBm. (s) OPERATING ENVIRONMENT: Temperature, 32 to 122 F (0 to 50 C). 12.1.2. Electrical (Single-Ended) (t) TYPICAL CURRENT DRAIN FROM –48Vdc: Model Idle Busy 3652-62 25mA 40mA 3652-68 20mA 25mA 12.1.3. Signaling (u) OPERATION: E&M or PLR.

This manual is also suitable for:

3652-68

Table of Contents