ALTISET II is a trademark of LB Altimeters, Denmark
LB Altimeters operates a policy of continuous development
Therefore, we reserve the right to make changes and improvements to any of the
products described in this guide without prior notice
WARNING
The ALTISET II, and all compatible units, are intended to be a backup device and must not be relied upon as your primary means of maintaining altitude awareness.
Use the ALTISET II , and all compatible units, at your own risk
Altimeters may give erroneous readings if you are tumbling or the altimeter is in a burble (wake). Chest mount altimeters are more vulnerable to this problem
compared to hand/wrist mounted altimeters. If you are in doubt about how this limitation affects your skydiving, consult a licensed instructor
DO NOT use this equipment unless you are currently participating in, or have successfully passed, an approved skydiving course
Please read ALL instructions carefully prior to use
Any ALTISET II compatible unit must be switched ON prior to entering the airplane
Page 1
WARNING The ALTISET II, and all compatible units, are intended to be a backup device and must not be relied upon as your primary means of maintaining altitude awareness. Use the ALTISET II , and all compatible units, at your own risk Altimeters may give erroneous readings if you are tumbling or the altimeter is in a burble (wake).
T u rn u n it O F F The ALTISET II automatically returns to the main window if no button has been pressed within 1 minute, and IR transmit is not active The ALTISET II automatically switches OFF if no button has been pressed within 2 minutes, and IR transmit is not active - Rev.
DISPLAY S ta rtu p When turning ON ALTISET II , the unit will display the main window M a in w in d o w The main window is the default window after the unit is turned ON, and starting point for any actions...
Use left button to return to a previous menu Values on the ALTISET II are changed and confirmed using the 3 buttons on the front of the ALTISET II : Press and hold left button to decrease value...
ALL SETTINGS ALL Settings are used to setup the basic Settings for all compatible LB altimeters Turn on ALTISET II or use to return to main window Press to scroll to select ALL Press to move forward to ALL Settings...
ALFA SETTINGS ALFA Settings are used to setup the ALFA digital Altimeter Turn on ALTISET II or use to return to main window Press to scroll to select ALFA Press to move forward to ALFA Settings D a te / Tim e...
Selecting this option will reset ALFA, with IrDA active Press to scroll to select RESET WITH IR Press to start IrDA transmission, and point towards any ALFA set in IrDA transceiver mode - Rev. 1.01 Page 8 of 16 ALTISET II...
ECHO SETTINGS ECHO Settings are used to setup the ECHO digital Altimeter Turn on ALTISET II or use to return to main window Press to scroll to select ALFA Press to move forward to ALFA Settings M e m o ry B a n k S e le ctio n...
Selecting this option will return ECHO to Factory Default settings Press to scroll to select FACTORY D. Press to start IrDA transmission, and point towards any ECHO set in IrDA transceiver mode - Rev. 1.01 Page 10 of 16 ALTISET II...
Selecting this option will reset ECHO, with IrDA active Press to scroll to select RESET WITH IR Press to start IrDA transmission, and point towards any ECHO set in IrDA transceiver mode - Rev. 1.01 Page 11 of 16 ALTISET II...
FUNCTIONALITY IR M o d e A ctiv a tio n – A L F A a n d E C H O Activate/Deactivate IR Mode on ALFA and ECHO digital altimeters, for communication with ALTISET II remote control Press and hold...
Always restart ALTISET II to attempt to remedy a single ERR code If the ERR code persists, then also perform battery change If the ALTISET II is still faulty after reset and battery change , it must be serviced by an LB Altimeters Service Center - Rev. 1.01...
200 to 1075 mbar Maximum allowable humidity: Up to 99,9% relative humidity Waterproof: Water resistant: Battery type: 2 x SANYO 2CR-1/3N batteries, or equivalent L&B part no.: 801000 NATO Stock no. 5820-22-616-5040 - Rev. 1.01 Page 14 of 16 ALTISET II...
The following conditions apply to the ALTISET II warranty: If within 12 months of the purchase of ALTISET II a defect or damage is identified by faulty manufacture, LB ALTIMETERS will repair the unit at no cost to the end user To make a claim under this warranty, send the unit to an authorized dealer or directly to LB ALTIMETERS together with the dated purchase invoice or receipt.
ALFA menu SETTINGS menu for ECHO units Input Values Confrm Value Decrease Increase Scroll to ECHO using Scroll to menu items using Press to step forward into ECHO menu AltiSet II - Rev. 1.01 Page 16 of 16...
Need help?
Do you have a question about the ALTISET II and is the answer not in the manual?
Questions and answers