CCS Technical Documentation
Calibration procedure with JBV-1
Select Read from phone to display the current calibration values that stored in
1
the phone memory. The values are displayed in the Phone Values field.
2
Select the ADC channel(s) you intend to calibrate.
3
Press Calibrate.
4
Calibration is automatically done regarding the calibration channel(s) that you
selected.
5
The candidate of the new calibration values is shown in the "calculated" field. If
the new calibration values are within the limit (please refer to the calibration
value limit table), Press Save to phone to store the new calibration value(s) into
the phone.
Select Read from phone to confirm if the new calibration value(s) are stored into
6
phone, correctly. If not, please try to store by selecting Write to PM again.
7
Close the Energy Management Calibration widow.
46
Figure 38: Energy Management Calibration window
COMPANY CONFIDENTIAL
Copyright © 2003 Nokia. All Rights Reserved.
NHL-10
Baseband Troubleshooting
ISSUE 2 01/2004