Download Print this page

E.P.E. Conseil CEMPROTEC 34 User Manual page 4

Electromagnetic field detector

Advertisement

1. Detection in Standard Mode:
The standard mode is very practical and allows the simultaneous
detection of electric and magnetic fields and high frequencies with
or without sound.
The device makes radiation easily "visible" therefore making the
sources more easily identifiable.
It can also be used to verify the protection solutions that have been
put in place to reduce exposure to waves.
1.
Briefly press the "on-off" button to switch the unit to standard
mode.
2.
Hold the detector with your arm slightly extended forward.
3.
Move around slowly to detect electromagnetic fields. The
device performs a new detection every two seconds.
NB: To activate or deactivate the sound, press and hold on the select
button.
2. Detection in FULL HF Mode:
The FULL HF mode enables an enhanced sensitivity detection that corresponds to the tolerance thresh-
olds of electro-sensitive people.
In Standard Mode, high-frequencies are detected by 8 LEDs. In FULL HF Mode there are 24 LEDs for
greater accuracy. The LEDs light up from LEFT to RIGHT from the BOTTOM to the TOP.
The detected high-frequency sound corresponds to a FINE ACOUSTIC ANALYSIS which is very useful.
This allows the sources to be identified by a sound proportional to the modulated frequency. In other
words, this function allows the ear to differentiate between different sources of radiation. For exam-
ple, if it is from the WiFI, a DECT phone, or an antenna. However, if the SOUND bothers you, it can be
easily turned off by pressing and holding the HF ONLY button.
Electromagnetic waves from base stations, Wifi/WiMax networks, or DECT phones, connected objects,
etc.
1.
Press the ON/OFF button briefly to turn on the standard mode.
2.
Press the "HF ONLY" button to activate the high-resolution HF mode
3.
Hold the detector with your arm slightly extended forward.
4.
Move around slowly to detect electromagnetic fields. The device performs a new detection
every two seconds.
Note: In this mode, all 24 LEDs are used for wave detection. The LEDs at the bottom of the display indi-
cate the lowest radiation level, while the LEDs at the top of the display show the highest level.
4
Standard Mode Table:
It indicates the power of radiation by each row of 8 LEDs and 14 levels. The table indicates the numeri-
cal values for the LEDs :
The magnetic field
with a 3D detection spectrum of 10 Hz to 5 kHz.
The electric field
with a detection spectrum of 10 Hz - 5 kHz.
The high-frequency field
with a detection spectrum of 1 MHz to 10 GHz.
Levels :
Levels :
0
1
2
3
4
LED :
LED :
G2
G1
G = green LED
G = green LED
G1
+
G2
+
Y1
Y= yellow LED
Y= yellow LED
G2
Y1
R = red LED
R = red LED
EF
EF
0
6
12
17
22
in V/m :
in V/m :
HF
HF
110
0
15
40
70
-in µW/m² :
-in µW/m
0,1
-in V/m :
-in V/m :
0
0,08
0,12
0,16
9
MF
MF
0
20
60
100
140
in nT :
in nT :
Hypersensitive mode table:
When the FULL HF function is activated, the unit detects only high-frequencies.
Radiation power is indicated by all 24 LEDs, from left to right from the bottom to top, with a detection
spectrum of 1 MHz to 10 GHz.
High-frequency
0
1
2
levels:
in µW/m² :
0
1
2,5
in V/m :
0
0,02
0,03
12
13
14
levels :
in µW/m²
300
400
550
in V/m :
0,33
0,38
0,45
5
6
7
8
9
10
11
Y1 +
Y2 +
Y3 +
R1 +
Y2
Y3
R1
Y2
Y3
R1
R2
26
30
34
39
45
52
60
150
200
300
500
750
1000
1250
0,23
0,27
0,33
0,43
0,53
0,61
0,69
180
220
300
400
650
1000
1500
3
4
5
6
7
8
10
20
40
50
75
100
0,06
0,09
0,12
0,14
0,17
0,19
15
16
17
18
19
20
750
1000
1250
1500
1750
2000
0,53
0,61
0,69
0,75
0,81
0,86
12
13
14
R2 +
R2
R3
R3
70
80
90
1500
1750
2000
0,75
0,81
0,86
2000
2500
3000
9
10
11
140
180
225
0,22
0,25
0,29
21
22
23
2250
2500
2750
1
0,92
0,96
5

Advertisement

loading