Page 2
The place where the magnetic base will be fixed must be clean and free from dust, chips, oil, grease, etc. The operator must always use protection equipment and the safety strap of the FE-45 drill when with the fixation position is not horizontal.
Page 3
Whenever replacing the cutters, turn off machine and do not use the rotation switch. Whenever replacing the cutters, turn off machine and do NOT use the rotation switch. TURN OFF THE MACHINE. When using annular cutters the operator must be cautious, for these tools are more fragile. There's no need to force the penetration of the cutter.
Page 4
Get the machine clean and free from oil and grease. Corrective maintenance: Electric motor Sparking: Check and replace the carbon brushes set. Excessive noise and vibration: Turn off the machine. Check and replace bearings, bushings and worn or broken parts of the drill. Motor stop: Check power supply, On/off switch, rotation control switch, electric cord, carbon brushes set, motor burnout, and potentiometer burn-out.
Page 5
ELECTRIC DIAGRAM OF ON/OFF SWITCH Rotation variation: Among all possible causes, the highest occurance is the variation in the electric current. Example: drill is working and another machine plugged in the same network provokes fall in current, causing a decrease or complete stop of rotation, possibly jamming or breaking the cutter.
Page 6
After that, you will have access to the set of screws (60) in order to fasten or replace them, in case of need. Use only original spare parts and always contact a Merax Authorized Assistance. Check list in our website:...