4. Turn off input power to unit before connecting or disconnecting other equipment. 5. Do not operate system in close proximity to flammable liquids. 6. Do not use standard Ethernet cables with IQ Power Systems. CAUTION – Electrical Shock Hazard...
24 VDC power. The AC adapter available with the Hub features a universal line voltage input and will operate on 100 to 240 VAC, 50/60 Hz. The Hub can provide power & communication for up to four IQ Power and four IQ Easy devices. The Bluetooth Adapter provides wireless communication between Hub connected devices and a Control Station;...
3. SPECIFICATIONS Input Power 24 VDC, 3.75A, negative ground from AC adapter or user supplied 4 IQ Power (RJ-45) One reserved for connection to Bluetooth Adapter; Connectors 4 IQ Easy (M12) LED Indicator Green POWER Operating Temp 50°C [122°F] max...
4. INSTALLATION NOTE – DO NOT USE standard Ethernet cables with IQ Power systems. Avoid permanent equipment damage by using only Simco-Ion modular cables. (Refer to Section 8, Parts and Accessories). Figure 1. IQ Power Crossover Modular Cable (black) Wire Diagram System Setup NOTE –...
Addressing of the IQ Power/IQ Easy devices allows for up to 10 devices to be set and monitored by the Control Station. Follow the procedure below to address the individual devices. 1. Plug the device to be addressed into the Control Station.
Control Station and IQ Power Hub. It may take 15-30 seconds for the communications to be established. Verify that the lights are illuminated as follows: 1. Power indicator: lit (green) 2. Standby: not lit 3. Connect: lit (green) NOTE –...
Page 9
IQ Power Hub IQ Power Wireless Link Figure 2. IQ Power Hub & Bluetooth Adapter Dimensions I Q P ower Wir ele s s L i n k 5 2 0 1 3 1 9 R e v B...
System Configuration The IQ Power Hub with Bluetooth Adapter serves to distribute power and provide communications over a small area for IQ Power/IQ Easy devices. Power for the devices is provided by either an available AC adapter or user provided 24 VDC.
AC adapter but wants to supply 24 VDC power to the IQ Power Hub, user supplied 24 VDC power may be applied via a removable 2-position pluggable header (3.81 mm / .150” centers). The connector accepts up to 16 AWG wire with a strip length of 7 mm [1/4”].
RJ-45 sockets, 1 through 4 on the Hub. IQ Easy devices connect to available M12 Connectors DEV1 through DEV 4 on the Hub. The IQ Power Hub with Bluetooth Adapter is an extension of the Control Station. As such, connection procedures, limitations, and device addressing should be carried out as described in the IQ Power Control Station instruction manual and in the Addressing section above.
For more detailed instructions on connecting devices to the Control Station, please refer to the instruction manual provided with the Control Station. Once the devices have been addressed and disconnected from the Control Station, connect the Bluetooth Adapter to the Control Station using the provided cable. Check to ensure that the power switch on the Bluetooth Adapter is in the “On”...
7. TROUBLESHOOTING NOTE – Only qualified service personnel are to perform troubleshooting tasks. PROBLEM CAUSE SOLUTION Make corrections to ensure 24 VDC is applied 24 VDC not applied to Hub to Hub Power LED not Line voltage not supplied to illuminated on Check line voltage and connections AC adapter...
9.14 meter [30 foot] Straight M12 Connector 5051844 Cable (RJ-45 to right angle M12 connector) IQ Power BPS to IQ Easy Sensor Bar with right angle connector at Sensor Bar end 4.57 meter [15 foot] Right Angle M12 Connector 5051841 9.14 meter [30 foot] Right Angle M12 Connector...
The warranty does not apply when Simco-Ion parts and equipment have been energized by other than the appropriate Simco-Ion power supply or generator, or when a Simco- Ion power supply or generator has been used to energize other than Simco-Ion parts and equipment.
Need help?
Do you have a question about the IQ Power and is the answer not in the manual?
Questions and answers