Download Print this page

HAKO Fleet-Recorder Assembly Manual page 6

For scrubmaster b75 r and scrubmaster b115 r

Advertisement

Fleet-Recorder Scrubmaster B75 R
1.2.3 Installing the buzzer
The connection lines of the
buzzer are sensitive to tension
stress!
Use cable ties at a distance
of > 50 mm to the buzzer.
Run the antenna cable (Fig. 4/1) in a
loop and fix it together with the P20
buzzer (Fig. 4/2) using cable ties
(Fig. 4/3).
1.2.4 Installing the W77 cable loom
1. Insert the 6-pole plug A01/X3 of the
W77 cable loom into the diagnosis
slot of control A01 (Fig. 4/4).
2. Connect the plug of the P20 buzzer
to the plug of the W77 cable loom
(Fig. 4/5).
3. Connect the 4-pole plug X78 of the
W77 cable loom to the same named
plug of the W60 cable loom.
4. Connect the plug of the
Fleet-Recorder A20/X1 to the
12-pole plug of the W77 cable loom.
5. To connect to the key switch,
connect plug X102 of the W77 cable
loom to the same named plug of the
W3 cable loom.
6
View A
1
3
2
5
Fig. 4
6
6
4
A

Advertisement

loading

Related Products for HAKO Fleet-Recorder

This manual is also suitable for:

5305.00