Download Print this page

Service Connections - Blodgett CB24-24E Installation Operation & Maintenance

Cb-e series electric steam boiler cabinets
Hide thumbs Also See for CB24-24E:

Advertisement

2.0 SERVICE CONNECTIONS

DRAIN: 2"IPS piped to open floor drain. No Solid Connection.
COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
HOT WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
S
STEAM TAKE-OFF CONNECTION: 3/4"IPS to operate adjacent equipment.
Field Wiring Electrical Connection to be as specified on data plate.
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water which fails to meet these standards should be treated by installation of a water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
OUTPUT
PHASE
kW
MAX. LBS/HR.
1
69
24
3
69
36
3
107
42
3
128
48
3
148
WIDTH
UNITS
A
inches
24
mm
8.75
610
36
inches
222
914
mm
DIMENSIONS ARE IN INCHES [MM]
NOTE: PRESSURE REDUCING VALVE -OPTIONAL
WATER QUALITY STATEMENT
Total dissolved solids
Total alkalinity
Silica
Chlorine
pH Factor
ELECTRICAL CHARACTERISTICS
208V
220V
115.4
109.1
66.6
62.9
99.9
94.5
116.6
110.2
N/A
N/A
DIMENSIONS
B
C
D
E
8.75
5.75
16.75
23
222
425
584
146
18
457
S
6 [152]
Less than 60 PPM
Less than 20 PPM
Less than 13 PPM
Less than 1.5 PPM
7.0-8.5
AMPS PER LINE
240V
380V
N/A
100.0
57.7
36.5
86.6
54.7
101.0
63.8
115.5
72.9
F
G
H
J
2.75
3.5
10.5
2.5
11.12
89
267
64
283
4.75
121
E
K
F
L
M
4
415V
480V
N/A
N/A
33.4
28.9
50.1
43.3
58.4
50.5
66.8
57.7
K
L
M
N
13
4.75
70
2.5
330
19.75
121
64
21.25
502
6.75
540
171
S
S
WIDTH
24 [610] or 36 [914]
P

Advertisement

loading

This manual is also suitable for: