Error Codes

Solid RED - The MRS-485 detected an error and no Modbus communications are in progress.
RED with random bursts of AMBER - The MRS-485 detected an error and AMBER is displayed when data are
received or transmitted over the RS-485 line
There are a number of conditions which are signalized in this way:
Current EEPROM Settings not initialized
Current EEPROM Settings have bad checksum
Factory EEPROM Settings not initialized
Factory EEPROM Settings have bad checksum
Unknown Sensor exponent value
Watchdog reset
Loaded Factory EEPROM Settings in EEPROM Current Settings
Latched sensor type different than registered sensor type
Unknown sensor type because registration failed
6.2

DIP Switch Settings Codes

RED/GREEN – Alternating every 200 milliseconds indicates that MRS-485 is in programming mode and waiting
for user to enter new settings using the 8 switches.
RED/OFF –
alternating every 200 milliseconds indicate that saving new settings failed.
GREEN/OFF – alternating every 200 milliseconds indicates that saving new settings passed.
RED/OFF alternating every 500 milliseconds indicates that selected Modbus address is not an accepted value.