Crestron Electronics DM-NVX-E30 Product Manual

Crestron Electronics DM-NVX-E30 Product Manual

Network av encoders/decoders

Advertisement

Quick Links

DM NVX® Network AV
Encoders/Decoders
DM-NVX-E30
DM-NVX-D30
DM-NVX-E30C
DM-NVX-D30C
DM-NVX-D80-IOAV
Product Manual
Crestron Electronics, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DM-NVX-E30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Crestron Electronics DM-NVX-E30

  • Page 1 DM NVX® Network AV Encoders/Decoders DM-NVX-E30 DM-NVX-D30 DM-NVX-E30C DM-NVX-D30C DM-NVX-D80-IOAV Product Manual Crestron Electronics, Inc.
  • Page 2 Crestron, the Crestron logo, 3-Series, Crestron Toolbox, Crestron XiO Cloud, DigitalMedia, DM NVX, and DM NVX Director are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Dolby and Dolby Atmos are either trademarks or registered trademarks of Dolby Laboratories in the United States and/or other countries.
  • Page 3: Table Of Contents

    Introduction ............................ 1 Physical Description ........................2 DM-NVX-E30 and DM-NVX-D30 ......................2 Front Panel, DM-NVX-E30 ........................ 2 Front Panel, DM-NVX-D30 ....................... 3 Rear Panel, DM-NVX-E30 and DM-NVX-D30 ................4 DM-NVX-E30C ............................5 DM-NVX-D30C ............................6 DM-NVX-D80-IOAV ..........................7 Front Panel ............................7 Rear Panel .............................
  • Page 4 Subscriptions ............................29 Using the Web Interface ........................29 Using SIMPL Windows ........................31 EDID (Extended Display Identification Data) ..................31 Background Image ........................... 34 Using the Web Interface ........................34 Using the Web Interface ........................38 Still Image Detection ..........................38 USB 2.0 Routing ............................
  • Page 5: Introduction

    IOAV also functions as a decoder only and is compatible with the Intel® OPS (Open Pluggable Specification). Compact in design, the DM-NVX-E30 and DM-NVX-D30 are designed to mount to a flat surface such as a wall. The DM-NVX-E30C and DM-NVX-D30C are designed to occupy the DMF-CI-8 card chassis.
  • Page 6: Physical Description

    DM-NVX-E30(C), DM-NVX-D30(C), and DM-NVX-D80-IOAV devices. DM-NVX-E30 and DM-NVX-D30 This section provides information about the front and rear panels of the DM-NVX-E30 and DM-NVX-D30. Front Panel, DM-NVX-E30 The following illustration shows the front panel of the DM-NVX-E30.
  • Page 7: Front Panel, Dm-Nvx-D30

    Output Impedance: 200 Ohms balanced, 100 Ohms unbalanced; Maximum Output Level: 4 Vrms balanced, 2 Vrms unbalanced NOTE: The analog audio output is functional only when the DM-NVX-E30 is receiving a 2-channel stereo input signal. Front Panel, DM-NVX-D30 The following illustration shows the front panel of the DM-NVX-D30.
  • Page 8: Rear Panel, Dm-Nvx-E30 And Dm-Nvx-D30

    Rear Panel, DM-NVX-E30 and DM-NVX-D30 The following illustration shows the rear panel of the DM-NVX-E30 and DM-NVX-D30. DM-NVX-E30 and DM-NVX-D30 Rear Panel PWR: Bicolor green/amber LED, indicates operating power supplied via the power  pack (sold separately), PoE+ compliant Ethernet switch, or injector/PSE;...
  • Page 9: Dm-Nvx-E30C

    Device control via CEC requires the use of a Crestron 3-Series or later control system. The HDMI connection requires an appropriate adapter or interface cable to accommodate a DVI or Dual-Mode DisplayPort signal. CBL-HD-DVI interface cables are sold separately. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 5...
  • Page 10: Dm-Nvx-D30C

    Device control via CEC requires the use of a Crestron 3-Series or later control system. The HDMI connection requires an appropriate adapter or interface cable to accommodate a DVI signal. CBL-HD-DVI interface cables are sold separately. 6 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 11: Dm-Nvx-D80-Ioav

    Red LED, indicates that the SETUP button is pressed and times out automatically. NOTE: If the DM-NVX-D80-IOAV decoder is connected to a DM-NVX-E30(C) or DM-NVX-35x(C) encoder, pressing the SETUP button on the DM-NVX-D80-IOAV for less than 10 seconds displays the decoder and encoder IP addresses. The IP addresses are shown on the OPS-supported display.
  • Page 12: Rear Panel

    7.1 surround sound audio • Analog audio output • Subscriptions • EDID (Extended Display Identification Data) • Background image • Still image detection • USB 2.0 routing • Test pattern generator • 8 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 13: Dmf-Ci-8 Chassis Details

    <ChassisSerialNumber_F> serial output join to report the serial number of the chassis in which the card is installed. Program the <CardSlotInfo_F> serial output join to report the slot number in which the card is installed in the chassis. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 9...
  • Page 14: Dm Nvx Director Virtual Switching Appliance

    The DM NVX Director section displays the following information: DM NVX Director hostname • Domain name, number, and slot number to which the DM NVX device is assigned • Status Tab – DM NVX Director 10 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 15: Crestron Xio Cloud Service Connection

    DM-NVX-E30C/DM-NVX-D30C Quick Start (Doc. 8346), or DM-NVX-D80-IOAV Quick Start (Doc. 8526) as appropriate. For information about using the service, refer to the XiO Cloud Provisioning and Management Service User Guide (Doc. 8214). Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 11...
  • Page 16: Fan Control

    Fan status is indicated as either of the following: Full On: The fan is running. • Off: The fan is not running. • Settings Tab – System Setup, Fan Control 12 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 17: Using Simpl Windows

    DM NVX encoder or a connection to a 1000BASE-T switch. If a direct connection between an encoder and decoder is detected, point-to-point mode is automatically enabled. Disable: Disables point-to-point mode • Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 13...
  • Page 18: Using Simpl Windows

    (right) or Off (left) position, respectively. The default setting is in the Off (left) position. To reset statistics, click Reset Statistics. • For additional information, refer to the online help of the web interface. 14 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 19: Using Simpl Windows

    Settings Tab – Stream, Advanced, Statistics Using SIMPL Windows For the DM-NVX-E30 and DM-NVX-E30C, configure stream statistics in Slot-01: Stream Transmit. For the DM-NVX-D30, DM-NVX-D30C, and DM-NVX-D80-IOAV, configure stream statistics in Slot-02: Stream Receive. Trigger the <StatisticsEnabled> digital input join to enable the reporting of statistics. To disable statistics, trigger the <StatisticsDisabled>...
  • Page 20: Using The Web Interface

    DM NVX web server • 172.30.160.90 is the IP address of the DM NVX device • preview_540px.jpeg is the file name of the image preview file • 16 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 21: Using Simpl Windows

    SIMPL Windows help file. Multicast TTL (Time-to-Live) NOTE: Multicast TTL configuration is applicable to the DM-NVX-E30 and DM-NVX-E30C only. Multicast TTL provides the ability to limit or extend the hop limit of a DM NVX stream that traverses routers. In IPv4 multicasting, routers have a TTL threshold assigned to each interface.
  • Page 22: Using The Web Interface

    5. Enable Auto Initiation by setting the Auto Initiation toggle switch in the On (right) position. The stream automatically restarts. NOTE: Disabling Custom TTL returns the TTL value to the default setting. Settings Tab – Stream, Advanced, Multicast TTL Configuration 18 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 23: Using Simpl Windows

    DSCP (Differentiated Services Code Point) NOTE: DSCP configuration is applicable to the DM-NVX-E30 and DM-NVX-E30C only. To implement Quality of Service (QoS), IP networks use the DSCP value. Within an IP packet header, the DSCP defines a value from 0 to 63 that maps to a certain traffic classification.
  • Page 24 Settings Tab – Stream, Advanced, Custom DSCP 20 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 25: Adaptive Bit Rate

    Adaptive Bit Rate NOTE: Adaptive bit rate is applicable to the DM-NVX-E30 and DM-NVX-E30C only. Adaptive bit rate functionality enables a DM NVX transmitter to automatically set the bit rate required for the input resolution of the stream; for example, the adaptive bit rate for a common resolution such as 1920x1080p@60Hz (1080p60) is automatically set to 400 Mbps.
  • Page 26: Using Simpl Windows

    Dolby® TrueHD, Dolby Atmos®, DTS HD®, DTS:X® and uncompressed linear PCM audio formats. To configure 7.1 surround sound audio, set the desired EDID (refer to the “ EDID” section on page 31). 22 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 27: Dm Nax Audio Over Ip (Aes67)

    The DM NAX (AES67) Audio section varies depending on whether the DM NVX • endpoint is a transmitter or receiver. For the DM-NVX-E30 and DM-NVX-E30C, refer to the “Configuring DM NAX (AES67) Audio for a DM NVX Transmitter” section that follows. For the DM-NVX-D30, DM-NVX-D30C, and DM-NVX-D80- IOAV, refer to the “Configuring DM NAX (AES67) Audio for a DM NVX Receiver”...
  • Page 28 Settings Tab - DM NAX (AES67) Audio Configuration for a DM NVX Transmitter For additional information, refer to the online help of the web interface. 24 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 29 On. If Auto Initiation is set to Off, start or stop the stream as desired. The following AES67 audio stream information is displayed: status, encoding format, encoding sample rate, bit rate, and number of channels. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 25...
  • Page 30 Settings Tab - DM NAX (AES67) Audio Configuration for a DM NVX Receiver 26 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 31: Using Simpl Windows

    DM NAX (AES67) audio in Slot-18-01: DM NAX (AES67) TX. In order for a DM NVX device to receive DM NAX (AES67) audio, configure DM NAX (AES67) in Slot-18-33: DM NAX (AES67) RX. For additional information, refer to the SIMPL Windows help file. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 27...
  • Page 32: Analog Audio Output

    Analog Audio Output NOTE: Analog audio output configuration is applicable to the DM-NVX-E30, DM-NVX- E30C, DM-NVX-D30, and DM-NVX-D30C. The analog audio output can provide a stereo line-level signal to feed a local sound system or sound bar. The output volume is adjustable via the web interface or SIMPL Windows.
  • Page 33: Subscriptions

    Move Up or Move Down icon in the Reorder column until the transmitter appears in the desired located in the list. In the Available Streams section, click Subscribe Checked or Subscribe for the • encoders that are to be subscribed to the decoder. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 29...
  • Page 34 3. Under the Settings tab, click Routing. In the Stream Routing section, select the desired encoder to be routed to the decoder. Settings Tab – Routing, Stream Routing For additional information, refer to the online help of the web interface. 30 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 35: Using Simpl Windows

    EDID (Extended Display Identification Data) NOTE: EDID configuration is applicable to the DM-NVX-E30 and DM-NVX-E30C only. EDID configuration allows management of the EDID that is to be sent to the upstream device connected to the HDMI input of the DM NVX device. If an EDID other than the default EDID is desired, use the web interface to configure the EDID.
  • Page 36 To select an EDID for the input: Click the Settings tab and then click Inputs. 2. In the Inputs table, click the Edit button. 3. In the EDID section, select the desired EDID. 32 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 37 Settings Tab – Inputs, EDID Configuration Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 33...
  • Page 38: Background Image

    From Local Device or From Remote Server. If From Local Device is selected, continue with step 5. If From Remote Server is selected, omit step 5 and proceed to step 6. 34 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 39 Refresh Rate list box. The refresh rate ranges from 1 to 65,535 minutes. The default setting is 60 minutes. To disable the background image, set the Background Image toggle switch in the Off (left) position (default setting). Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 35...
  • Page 40 Settings Tab, Outputs, On-Screen Display, Background Image 36 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 41 Settings Tab, Outputs, Background Image Retrieval from Local Device, Adding an Image Settings Tab, Outputs, Background Image Retrieval from Local Device Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 37...
  • Page 42: Using The Web Interface

    Still image detection is reported in the top-level programming slot of SIMPL Windows via the <StillImageDetection_F> analog output join. 38 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 43: Usb 2.0 Routing

    USB 2.0 Layer 3 data transport supports USB signal extension in DM NVX point-to-point applications across VLANs. USB-EXT-DM and USB-NX2 devices do not support Layer 3. To configure USB routing, use the web interface or SIMPL Windows as discussed in the following sections. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 39...
  • Page 44: Using The Web Interface

    NOTE: When DM-NVX-35x(C) firmware is upgraded from version 2.0.3900.00056 or earlier to a later version, automatic USB pairing is disabled. If factory default settings are restored, automatic USB pairing is enabled. 40 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 45 For Layer 2, remove the current entry or enter 00:00:00:00:00:00 in the Remote Device ID 1 text box. For Layer 3, enter an unused IP address in the Remote Device ID 1 text box. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 41...
  • Page 46: Using Simpl Windows

    1d = Remote (REX). For the DM-NVX-D80-IOAV, set USB Mode to 1d = Remote (REX). For the DM-NVX-35x(C) to be paired with the DM-NVX-D80-IOAV, set USB mode to 0d = Local (LEX). 42 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 47 5. Do either of the following: Trigger the <Pair> digital input join on each DM NVX device (LEX and REX). • Trigger the <AutomaticUSBPairingEnabled> digital input join on each DM • NVX device (LEX and REX). Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 43...
  • Page 48: Test Pattern Generator

    Test Pattern Generator NOTE: Test pattern generator is applicable to the DM-NVX-E30(C). The built-in test pattern generator can be used to ensure that video streaming is occurring and can also be used as a tool for the adjustment, calibration, and alignment of displays, video walls, and projectors.
  • Page 49 In the Test Pattern drop-down list, select the desired test pattern. Available options are listed in the following table. TEST PATTERN OPTION TEST PATTERN Off (default setting) Disables the test pattern generator SMPTE ColorBars Black White Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 45...
  • Page 50 Vertical Lines Grid Color Bars Gray Gradient 46 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 51: Using Simpl Windows

    Configure the test pattern generator in Slot-12: Test Pattern Generator. Set the <TestPatternGenerator> analog input join to the desired test pattern. Set the <TestPatternResolution> analog input join to the desired value. For additional information, refer to the SIMPL Windows help file. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 47...
  • Page 52: Enterprise-Grade Security

    To configure authentication management in the web interface, click the Security tab. For detailed information, refer to the online help of the web interface. Security Tab – Authentication Management of Users and Groups 48 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 53: Ieee 802.1X Authentication

    LAN. To manage trusted certificate authorities, go to the Action menu in the upper-right corner of the web interface and select Manage Certificates. Action Menu - Manage Certificates Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 49...
  • Page 54 To configure IEEE 802.1X authentication in the web interface, click the 802.1x Configuration tab. For detailed information, refer to the online help of the web interface. 802.1X Authentication Tab 50 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 55: Automatic Firmware Update

    22. Entry of a port number is necessary only if the port number differs from the default value of 21 or 22. path is the path to the manifest file • filename consists of the name and extension (.mft) of the manifest file • Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 51...
  • Page 56: Igmp Snooping

    The IGMP snooping support version (v2 or v3) is configurable in the web interface. The desired version can be selected under the Settings tab in the System Setup - Network Interface section. The default setting is v2. 52 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 57 DM NVX devices do not support random-timer and source-specific queries. • As a host, a DM NVX device configured for support of IGMPv3 is compatible with a • network switch (IGMP querier) that is configured for IGMPv2. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 53...
  • Page 58 If the network switch supports IGMP fast leave, enable the configuration at the • port, global, or VLAN level. If the network switch supports PIM snooping, enable the configuration to prevent • flooding IP multicast traffic toward multicast router (mrouter) ports. 54 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 59: Troubleshooting

    The video is intermittent. The HDMI or Ethernet cable Verity that all cables are connected connections are faulty. securely. (Applicable to the DM-NVX-E30 The incorrect EDID is selected for Select the correct EDID. and DM-NVX-E30C) A message the HDMI input.
  • Page 60 Set the audio source to analog audio. DM-NVX-35x[C] encoders only) An incorrect audio source is selected. The audio is multichannel Switch the audio input to on a DM-NVX-E30 or 2-channel audio. DM-NVX-E30C, which do not downmix a 2-channel signal from a multichannel surround sound source.
  • Page 61: Appendix: Device Discovery

    The associated host name, IP address, and firmware version are also displayed. 3. In the Device Discovery Tool list, double-click the name of the DM NVX device (DM-NVX-E30, DM-NVX-D30, DM-NVX-E30C, DM-NVX-D30C, or DM-NVX-D80-IOAV). The Authentication dialog box opens.
  • Page 62 The user name and password are case sensitive. 7. Click Sign In. The Status page of the DM NVX device opens. For additional information, refer to the online help of the web interface. 58 • DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV Product Manual – DOC. 8425D...
  • Page 63 This page is intentionally left blank. Product Manual – DOC. 8425D DM-NVX-E30(C)/DM-NVX-D30(C)/DM-NVX-D80-IOAV • 59...
  • Page 64 Crestron Electronics, Inc. Product Manual – DOC. 8425D 15 Volvo Drive, Rockleigh, NJ 07647 Tel: 888.CRESTRON 7/9/21 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.

This manual is also suitable for:

Dm-nvx-d30Dm-nvx-e30cDm-nvx-d30cDm-nvx-d80-ioav

Table of Contents