1.
Expansion pipe
2.
1. Cable tie
1. Inside chimney
2. Inside chimney bracket
3. Outside chimney
1.
Install the outside chimney bracket onto the outside
chimney with 2 pcs ST4*8mm screws, make the inside
chimney can be flexed freely inside. See pic 4.
2.
Make the hood hang on the wall mounted screws in the
fixed position, adjusting the cooker hood position, fix the
cooker hood with 2 pcs ST4*30mm safety screws. See pic 5.
Note: The two safety vents are positioned on the back
housing, with a diameter of 6mm.
3.
Adjust the height of the inside chimney to the position of
the inside chimney bracket and fix the inside chimney and
outside chimney with 4 pcs ST4*8mm screws. See pic 6.
V-flap
Hints For Exhaust Duct Installation
The following rules must be strictly followed to obtain optimal air ex-
traction:
Keep exhaust duct short and straight
Do not reduce the size or restrict the exhaust duct
When using the flexible duct always install the duct pulled taut to
minimize pressure loss
Failure to observe these basic instructions will reduce the
performance and increase noise levels of the range hood.
Any installation work must be carried out by a qualified electrician
or competent person.
Do not connect the ducting system of the hood to any existing
ventilation system which is being used for any other appliance ,such
as warmer tube, gas tube , hot wind tube.
The angle of the bend of the ventilation pipe should not be less than
120º; you must direct the pipe horizontally, or, alternatively, the
pipe should go up from the initial point and should be led to an
outer wall.
After the installation ,make sure that the cooker hood is level to
avoid grease collection at on end.
Ensure the exhaust ducting selected for installation complies with rele-
vant standards and is fire retardant.