1128 INTERNATIONAL
WIRELESS GLASSBREAK DETECTOR
Installation Guide
Figure 1: 1128 International
Wireless Glassbreak Detector
DESCRIPTION
The 1128INT Wireless
Glassbreak Detector is a fully-
supervised, low current shock
and glassbreak sensor that
provides detection coverage
up to 20 ft from framed
glass mounted in an outside
wall. The 1128INT features
128-bit AES encryption.
You can mount the detector
on the ceiling or on an
opposing wall for maximum
flexibility and coverage. The
1128INT operates using the
supplied 3 V lithium battery.
Compatibility
All DMP 1100 Series
Wireless Receivers Version
700 and higher. Glassbreak
Walk Test is available on
1128INT Version 7.0.0.2
and higher and with XT/
XR Series Version 693 and
higher. See last page for
compatibility details.
What is Included?
One 1128INT Wireless
Glassbreak Detector
One 3 V lithium
CR123A battery
Hardware Pack
1
PROGRAM THE PANEL
When programming the 1128INT in the panel, refer to the panel
programming guide as needed.
At a keypad, enter 6653 (PROG) to access the
1.
PROGRAMMER menu.
Press CMD until ZONE INFORMATION displays and
2.
press a top row select key or area.
3.
Enter the wireless ZONE NO and press CMD.
Enter the zone name and press CMD.
4.
Select NT (night) the ZONE TYPE.
5.
Select the AREA NO and press CMD.
6.
At the NEXT ZN? prompt, select NO and press CMD
7.
until WIRELESS?
Select YES when WIRELESS? displays and press CMD.
8.
Enter the eight-digit SERIAL# and press CMD.
9.
10.
Enter the SUPRVSN TIME and press CMD.
11.
At the NEXT ZN? prompt, select YES if you are finished
programming the zone. Select NO if you would like to
access additional programming options.
12.
In SYSTEM OPTIONS, at the 1100 ENCRYPTION
prompt, select ALL to only add encrypted wireless
devices to the system. Select BOTH to allow both
encrypted and non-encrypted wireless devices to be
programmed.
13.
The default passphrase appears at ENTER
PASSPHRASE. Press CMD to keep the default. Press any
select key or area to change the passphrase and enter
an 8-character hexadecimal string (0-9, A-F).
2
INSTALL THE BATTERY
Keep in mind, when setting up a wireless system, program zones
and connect the receiver before installing the included CR123A
battery in the transmitter.
1.
Remove the holding screw at the lower end of the
1128INT case and gently lift off the cover. See Figure 2.
2.
Observing polarity, place the battery in the holder and
press into place. See Figure 3 for the battery location.
displays.

Advertisement

loading

Summary of Contents for Digital Monitoring Products 1128

  • Page 1 Enter the wireless ZONE NO and press CMD. Enter the zone name and press CMD. Figure 1: 1128 International Select NT (night) the ZONE TYPE. Wireless Glassbreak Detector Select the AREA NO and press CMD.
  • Page 2 Where white noise (air compressor) is present • Rooms smaller than 10'x10' • Rooms with multiple noise sources like televisions, sinks, speakers, etc. • Excessively humid rooms Note: Program the 1128INT as a night zone to help avoid false alarms. 1128 INSTALLATION GUIDE DIGITAL MONITORING PRODUCTS...
  • Page 3 If the 1128INT is in range, it will flash the LED red for 3 seconds to indicate it detected the crash. The 1128INT will remain in testing mode for 30 minutes or until the panel is reset. 1128 INSTALLATION GUIDE DIGITAL MONITORING PRODUCTS...
  • Page 4 I N T R U S I O N • F I R E • A C C E S S • N E T W O R K S © 2021 Digital Monitoring Products, Inc. 2500 North Partnership Boulevard...