LRX 2150 NEW ELECTRONIC PANEL
Single-phase electronic control unit for the automation of swing
gates with incorporated radio receiver.
- Mod. LG 2150 New
- Mod. LRS 2150 New
- Mod. LRS 2150 New SET
- Mod. LRH 2150 New
I
MPORTANT FOR THE USER
- The device can be used by children over 8 years of age
and persons with reduced physical or psychological
abilities or with little knowledge and experience only if
supervised or educated in its operation and safe use, in
order to also understand the dangers involved in its use.
- these instructions are also available at the website
www.seav.com
- Do not allow children to play with the device and keep
the radio controls away from their reach.
- Frequently examine the system to detect any signs of
damage. Do not use the device if it is in need of repair
work.
-Always remember to disconnect the power supply before
carrying out any cleaning or maintenance.
- Cleaning and maintenance must not be carried out by
unsupervised children
- ATTENTION: keep this instruction manual safe and
observe the important safety requirements contained
herein. Failure to comply with the requirements may
cause damage and serious accidents.
I
the
MPORTANT FOR
INSTALLER
− Before automating the gate, check that it is in good
conditions, in compliance with the Machinery Directive
and with EN 12604.
− Check that the location where the installation is
located enables compliance with operating temperature
limits specified for the device.
− The safety of the final installation and compliance with
all prescribed Standards (EN 12453 - EN 12445) is the
responsibility of the person who assembles the various
parts to construct a total closing.
− Once installation is finished, it is recommended that
all
necessary
checks
programming of the control panel and correct installation
of safety devices) to ensure that compliant installation
has been performed.
− The control unit does not have any type of isolating
device for the 230 Vac line. It is therefore the
responsibility of the installer to set up an isolating device
inside the system. It is necessary to install an omnipolar
switch, surge category III. It must be positioned to
provide protection from accidental closing, pursuant to
point 5.2.9 of EN 12453.
− For the power supply cables, use flexible cables in an
insulating
sheath
in
(H05RN-F) with a minimum conductor section of 1mm2
− The various electrical components external to the
control unit must be cabled in accordance with standard
EN 60204-1 as amended, and as set forth in point 5.2.7
of EN 12453. Power cables may have a maximum
: Without radio receiver
: 433.92 Mhz
: 433.92 Mhz "narrow band"
: 868.3 Mhz "narrow band"
be
performed
(appropriate
harmonised
polychloroprene
GB
diameter of 14 mm. The fixing of power and connection
cables must be secured through the use of "optional"
cable glands supplied. Pay careful attention when
fastening the cables so that they are anchored in a stable
manner.
Furthermore, care is required when drilling holes in the
outside casing where connecting and power supply
cables will pass, and when assembling the cable glands,
so that everything is installed so as to maintain the
panel's IP protection characteristics.
− The assembly of a push button panel for manual
control must be completed positioning the push button
panel in such a way that the user is not placed in a
dangerous position.
− The rear part of the casing is equipped with
fittings for wall mounting (it is possible to drill holes for
installation with plugs, or there are already holes
available
for
implement all necessary measures to achieve an
installation that does not alter the IP protection.
− The gear motor used to move the gate must comply
with the requirements of point 5.2.7 of EN 12453.
− The D.S. Power Supply output must be dedicated to
the power supply of the photocells only. It cannot be
used for other applications.
− With every operation cycle, the control unit performs
the photocell operating test, ensuring protection against
the rupture of Category 2 crush-proof devices, in
accordance with point 5.1.1.6. of EN 12453. Accordingly,
if the safety devices are not connected and/or are not
working, the control unit is not enabled for operation.
− The safety function ensured by the control unit is
active only during closing, therefore, protection on
opening must be ensured in the installation phase with
measures (guards or safety distances) independent of
the control circuit.
− For proper functioning of the radio receiver, if using
one or more control units, the installation at a minimum
distance of at least 3 metres one from the other is
recommended.
:
The electronic control unit:
LG 2150 New - LRS 2150 New - LRS 2150 New SET
they comply with the specifications of the Directives
R&TTE 99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC.
installation
with
screws).
- LRH 2150 New
Plan
and

Advertisement

loading

Summary of Contents for EasyGate LRX 2150 New

  • Page 1 14 mm. The fixing of power and connection LRX 2150 NEW ELECTRONIC PANEL cables must be secured through the use of "optional" cable glands supplied. Pay careful attention when Single-phase electronic control unit for the automation of swing gates with incorporated radio receiver.
  • Page 2: Technical Data

    Pedestrian Passage: TECHNICAL DATA: The control unit allows only Motor 1 to be activated using either the radio control ( CODE PED. LED on) or the push button - Power supply 230 Vac 50-60Hz 1600W max. panel ( PED ), for the programmed time. ( T.MOT. PED. LED ). - Flashing light output : 230 Vac 500 W max.
  • Page 3 If it is necessary to modify the operating time of the motors, The SET key: this programs the information according to the programming must be carried out when the gate is closed, as type of function previously selected with the SEL button. follows: use the SEL key to move to the flashing T.MOT LED.
  • Page 4: Extended Menu

    alternately), with the SEL key position on the flashing of EXTENDED MENU 1 INB.CMD.AP LED then press the SET key, the INB.CMD.AP The control unit is supplied by the manufacturer with the will simultaneously switch permanently possibility of selecting only the main menu functions. programming is completed.
  • Page 5 the PED. commands. Repeat the procedure if you wish to A) AUT/P-P ( Follow Me ) : restore the previous configuration. It is possible to set the "Follow Me" function on the control unit: this function can only be programmed if a Pause Time has already been programmed, and it is used to shorten the Pause F) T.
  • Page 6 of the LED signal lights flash. Once the photocells are running correctly again, the control unit is ready for normal operation. This ensures monitoring against failures, in compliance with EN 954-1, Category 2. Control input test: On each low voltage control input, the control unit uses a LED signal to make the status readily known.