Page 2
Skip-Line ® is a registered trademark of Skip-Line, Inc., for pavement marking controls and related products and services. SC-12 Road Marking Control System - Installation and Operation Manual 2 ...
Page 3
SC-12 Road Marking Control System - Installation and Operation Manual 3 ...
Page 4
Left White Offset Left Bead Offset Right Air Offset Right Yellow Offset Right White Offset Right Bead Offset SC-12 Road Marking Control System - Installation and Operation Manual 4 ...
Warnings, Warranty, and Disclaimer WARRANTY Each unit of the SC-12 system is covered by a 30-day money-back guarantee. Buyer is responsible for determining suitability of this product for intended application prior to engaging in any contract that would rely on product functionality.
Page 6
SC-12 Road Marking Control System - Installation and Operation Manual 6 ...
Bead Offset 19 Pattern Preview 20 Rate Indicators 20 Feature Status Indicators 21 Status Indicators 21 Information System 22 Quick Setup 23 Mode 23 SC-12 Road Marking Control System - Installation and Operation Manual 7 ...
Page 8
41 Switch Test 41 Input Test 42 Button Test 42 About 43 Other Menus 44 Splash Screen 44 USB Menu 44 Side Configuration 44 SC-12 Road Marking Control System - Installation and Operation Manual 8 ...
Page 9
Message Descriptions 54 Master Box Switches 57 Appendix A: Glossary 58 Appendix B: Making a Communications Cable 59 Appendix C: Repairs Form 60 SC-12 Road Marking Control System - Installation and Operation Manual 9 ...
Skip-Line to see if it is possible. The SC-12 system is comprised of a network of core devices. At a minimum, the devices required for this core system are: Core Skipper ...
1.1 Unit Descriptions SC-12 units work together to provide both operator interface and output control of the vehicle hardware. The following are descriptions for each of the basic units. The M aster Control Box provides the primary ...
1.2 Optional Units The SC-12 system can be easily expanded, usually by simply adding a device to any unused port on a Hub. Your system may or may not have devices from the following list—if it does, further information is provided in separate reference documents.
2. Specifications Please observe the following operational and storage specifications for each of the basic SC-12 devices. Operation or storage outside of these specifications may reduce the life of the device and, in some cases, void the warranty. Minimum ...
3. Installation Installation of the SC-12 system requires both physical installation of the boxes and communications cabling. 3.1 Preparing the installation Check that the following are ready before getting started: Select mounting locations for each SC-12 component. ➢ Plan routes for communications cables from each box to closest hub box. ...
Do not leave dangling cables connected to hubs. Improperly terminated cables can cause communications issues. Important Note! The SC-12 system is now ready to be configured. SC-12 Road Marking Control System - Installation and Operation Manual 15 ...
4. Menu System The Skip-Line color LCD menu system is simple and intuitive, yet more capable than older skip timer menu systems. There are two navigation options—joystick and pushbutton. Either input type is equivalent, and will be referenced with the same functions throughout this section.
If a menu does not have a sub-menu, pressing down will enter an A ction Screen . Pressing and holding returns the Cursor to the menu bar on all Action Screens. SC-12 Road Marking Control System - Installation and Operation Manual 17 ...
The Main Screen is the recommended screen to use during striping operations. It is organized into several sections. SC-12 Road Marking Control System - Installation and Operation Manual 18 ...
( S ee section 4.5.2, G un Delays f or more information on Gun Delays. ) . SC-12 Road Marking Control System - Installation and Operation Manual 19 ...
Extend to 1.0', and Bead Offset to -0.5'. Then, during operations, only the Bead Offset will need to be shifted in order to adjust for truck speed and wind variables. SC-12 Road Marking Control System - Installation and Operation Manual 20 ...
Gun colors are shown on the preview, which helps the operator clearly see which guns will be counting towards application rates. SC-12 Road Marking Control System - Installation and Operation Manual 21 ...
Note that wet thickness will not match dry thickness measurements, due to material shrinkage. Refer to your road marking material vendor for more information. Info SC-12 Road Marking Control System - Installation and Operation Manual 22 ...
Status Indicators There are several s ystem status indicators that help show what is currently detected by or occurring on the skip timer. SC-12 Road Marking Control System - Installation and Operation Manual 23 ...
Messages are i nfo , w arning , e rror ) . Warning a nd E rror Messages w ill automatically disappear after the problem is SC-12 Road Marking Control System - Installation and Operation Manual 24 ...
➢ Black : Black patterns are enabled, per the configuration in the Setup menu. ➢ Marker: Marker layout patterns are enabled, per the configuration in the Setup menu. SC-12 Road Marking Control System - Installation and Operation Manual 25 ...
Page 26
The C ounter Channel menu provides access to distance and volume usage counters. Clearing the counter channels is common at the beginning of a new job. SC-12 Road Marking Control System - Installation and Operation Manual 26 ...
Page 27
Stripe width and pattern ( s olid or s kip ) are tracked respectively under L eft Guns and R ight Guns . SC-12 Road Marking Control System - Installation and Operation Manual 27 ...
Page 28
Paint usage by pump is tracked under P umps . SC-12 Road Marking Control System - Installation and Operation Manual 28 ...
Page 29
➢ When Gun 1 is solid and Gun 2 is skip, count into Skip-Solid. ➢ When the width of Gun 4 is 8", count into White 8". SC-12 Road Marking Control System - Installation and Operation Manual 29 ...
Page 30
Average will calculate over the whole job and is the default way to track the thickness. Note that other general items may be added to this list for various future system functions. SC-12 Road Marking Control System - Installation and Operation Manual 30 ...
Page 31
Overspeed and Underspeed alarms for familiarity. In systems without a speaker there will be no audio que. However, in the main screen the speed will be displayed in red SC-12 Road Marking Control System - Installation and Operation Manual 31 ...
Page 32
Scroll down using , and note that for systems with more than five material guns, you may need to scroll down to further pages. SC-12 Road Marking Control System - Installation and Operation Manual 32 ...
Page 33
➢ IMPORTANT : Do not correct time factors with distance. Only distance factors should be corrected with distance, otherwise, the skip timer will not be as accurate in placing SC-12 Road Marking Control System - Installation and Operation Manual 33 ...
Page 34
If the desired line length is ten feet, then in the above example the line marked 1 is SC-12 Road Marking Control System - Installation and Operation Manual 34 ...
Page 35
This is the recommended process for calibration. Alternately, select E dit Calibration... to view or directly modify the calibration number. SC-12 Road Marking Control System - Installation and Operation Manual 35 ...
Page 36
If there was an error, verify the motion sensor is installed correctly. The motion pulse source should provide between 2 pulses per foot and 20 pulses per foot. SC-12 Road Marking Control System - Installation and Operation Manual 36 ...
Page 37
This is the recommended process for calibration. Alternately, select E dit Calibration... to view or directly modify the calibration number. SC-12 Road Marking Control System - Installation and Operation Manual 37 ...
Page 38
4.5.4 Extras Some features are not part of the standard package, and are organized under other menus when purchased with the system. Marker Layout SC-12 Road Marking Control System - Installation and Operation Manual 38 ...
Page 39
Gun 1 is on SOLID, and Gun 3 is on SKIP. Gun 1 has been set to dot at 5’ intervals, while Gun 3 is set to do a 10’ Stripe of dots at 2.5’ spacing. SC-12 Road Marking Control System - Installation and Operation Manual 39 ...
Page 40
➢ Equidistant : Allows you to set the distance of the Stripe or Cycle, and the number of dots desired in that distance. The dots will be separated equally across the entered distance. SC-12 Road Marking Control System - Installation and Operation Manual 40 ...
Page 41
If the dot is small or if the gun does not have enough time to turn on, you may need to adjust P aint Gun Delays. Midspot length is also determined by the Dot Length parameter. SC-12 Road Marking Control System - Installation and Operation Manual 41 ...
Page 42
○ Fore Shadow : The length of black paint to be applied before the beginning of the stripe. ○ Aft Shadow : The length of black paint to be applied after the end of the stripe. SC-12 Road Marking Control System - Installation and Operation Manual 42 ...
Page 43
Important Note! The C arriage Layout menu is located under the G un Setup menu. SC-12 Road Marking Control System - Installation and Operation Manual 43 ...
Page 44
Rank 1: Y ellow Guns (Gun 1, Gun 2) R ank 2: W hite Guns (Gun 3, Gun 4, Gun 5) SC-12 Road Marking Control System - Installation and Operation Manual 44 ...
Page 45
More information on C arriage Layout c an be found in the C arriage Layout Manual Insert . SC-12 Road Marking Control System - Installation and Operation Manual 45 ...
Page 46
Remove load power and/or disconnect any equipment that would cause a safety hazard or undesired effects if a switch engaged that equipment. Important Note! SC-12 Road Marking Control System - Installation and Operation Manual 46 ...
Page 47
Scroll your cursor to the B egin Button Test option and navigate right to begin. SC-12 Road Marking Control System - Installation and Operation Manual 47 ...
Page 48
Refer to this page to find your particular system's revision number. This information, along with the model and serial numbers of your device, speeds troubleshooting efforts. SC-12 Road Marking Control System - Installation and Operation Manual 48 ...
Page 49
➢ Press and hold the right navigation button, or hold the joystick to the right, then apply power to the skip timer. ➢ This will enter the B ox Configuration menu. SC-12 Road Marking Control System - Installation and Operation Manual 49 ...
Page 50
➢ MOTION: This will simulate speed on the skip timer. ➢ PUMPS: This will simulate pump strokes. ➢ BOTH: T his mode will simulate both pump strokes and speed. SC-12 Road Marking Control System - Installation and Operation Manual 50 ...
Page 51
In the P umps Demo Mode y ou will be able to view a simulation of pump strokes. These are reflected in the Counter Channels. SC-12 Road Marking Control System - Installation and Operation Manual 51 ...
Page 52
The B oth Demo Mode w ill simulate both motion and pump strokes. SC-12 Road Marking Control System - Installation and Operation Manual 52 ...
Page 53
SOLID FT SKIP FT Gun 3 (White 4.00") 1751 White Subtotal: 1751 White Usage: 5.3 gal White App Rate: 15.2 mils* White Cal Number: 0.2537 SC-12 Road Marking Control System - Installation and Operation Manual 53 ...
Page 54
5.5' is entered as a bead distance offset, and the vehicle subsequently is operating at 10MPH, the beads will arrive 2.3' before the paint. This is obviously SC-12 Road Marking Control System - Installation and Operation Manual 54 ...
Page 55
It is recommended to attach a flag or identifier to the vehicle at the desired datum point. Then, measure from the datum point to the front material gun, as shown in the illustration below: SC-12 Road Marking Control System - Installation and Operation Manual 55 ...
Page 56
Enter the measured Datum Length distance (see 4.5.1, “Datum”) and then enable Datum Point usage in the Quick Setup menu to engage this feature. SC-12 Road Marking Control System - Installation and Operation Manual 56 ...
Page 57
5.4 In-Field Software Updates Software updates can be applied to Skip-Line skip timers in the field using a file, delivered via email or web download, placed on a USB flash drive. This provides a quick and easy way to provide new features, functionality, or bug fixes remotely without vehicle down time.
Page 58
Update files are created on a serial number basis. Attempting installation of an update file created for a different serial number will fail. Make sure your OEM and/or Skip-Line has the correct serial numbers prior to requesting an update. USB ...
Page 59
USB port —unplug any other devices. ➢ If the device was a USB flash drive, it is not compatible— try a different USB drive. SC-12 Road Marking Control System - Installation and Operation Manual 59 ...
Page 60
No communication with Core communicate with the Core Skipper device Skipper. in order to operate, since the Core Skipper is the central computer for the system. SC-12 Road Marking Control System - Installation and Operation Manual 60 ...
Page 61
Contact Skip-Line for service. Switch communication error. Check The SC-12 master box has had an internal cables. failure. Contact Skip-Line for service. SC-12 Road Marking Control System - Installation and Operation Manual 61 ...
Page 62
If you suspect that a switch is malfunctioning due to damage or wear, use the Switch Test menu to verify the switch status. SC-12 systems are custom built to order. Your unit may have fewer or additional switches and possibly with slightly different labels than those listed. ...
Page 63
Appendix A: Glossary Hub: A hub provides clean, filtered power and communications to the other units in the SC-12 system. It also shows diagnostics for each port, as well as general fault conditions. Core Skipper: T his is the same as the S lave Box on Legacy devices. This unit makes centralized command decisions for the entire system.
Page 64
Appendix B: Making a Communications Cable Communications cables for the SC-12 system follow the EIA/TIA 568-B cable wiring standard. These are commonly referred to as Cat5, RJ45, or simply as a network patch cable. A communications cable should be constructed using the following pin assignments on both ends of the cable.
Page 65
Appendix C: Repairs Form The SC-12 Control System is field-updateable and many issues may be fixed using the U SB Remote Update process ( S ee section 5.4 I n-Field Software Updates f or more information on the USB Remote Update process ) . If an issue has been isolated to a hardware malfunction and needs to be sent in for repairs, there is a form that can be filled out to help streamline the process.
Page 66
SC-12 Road Marking Control System - Installation and Operation Manual 66 ...