Söllnerstr. 9

Web-User

Here is the form for the input of the WEB-Interface users. Per user, different authorizations can be
assigned. In principle, only one user can make changes with "SU". U1 - U5 is only allowed to operate the
interface. In the S7 firewall expansion modules, "U1" - "U5" have more precisely specified operating rights.

S7-Firewall-settings

The PLC firewall connections result from the combination of HMI / PG station and PLC station

S7-Firewall operation

Modi
Description
off
no active Firewall
WAN port and LAN ports have separate IP networks. All functions and purchased
S7-Firewall Router
options of the TeleR <4> / sup> can be used
WAN port and LAN ports are an IP network. Only IP address ranges entered in the WAN
page are handled.
for example IP WAN 192.168.2.15
S7-Firewall Classic
IP LAN: 192.168.3.3
If a device with the IP 192.168.3.6 is connected, this is not treated until a
192.168.3.xxx address is entered in the WAN

Enter the HMI / PG stations

Parameter
Possible setting Purpose
Nr.
Automatic
Name
Free from the user station name
yes (x)
active
no ()
IP address of the
IP-Address
HMI / PG device
MAC address of
MAC-Address
the HMI / PG
device
S7-Firewall quick start guide
92637 Weiden
info@traeger.de
consecutive number
Connections to this station are handled by the firewall
Connections to this station are not processed, i.e. they are blocked
Identification of the sender Input is essential
Identifies the HMI / PG additionally via the MAC address. 00: 00: 00:
00: 00: 00 means that the MAC address is not checked. If the value is
not equal to 0, the MAC address of the station must match the input
+49 (0)961 48 23 0 0