5.
Strip the leads of the communication cable wires back ¼ in. Insert the
wires into the connector screw terminals. Using a small flat-blade
screwdriver, secure the wires with the COM PORT (J7/J8) terminal
screws. Note: Multiple wires may be inserted into a single screw
terminal. Be sure to match the color-coding of the wires:
Pin 4 - Red = +15 VDC
Pin 3 - Yellow = +DT
Pin 2 - Green = -DT
Pin 1 - Black = GND
IntelliTouch
®
(J7/J8) or
EasyTouch
®
System COM Ports
(J20) screw terminal
connector
6.
After the communication cable connection has been completed; close
the Outdoor Control Panel and tighten the two retaining screws.
Reinstall the High Voltage Panel: Insert the panel's three tabs into the
lower slots on the enclosure. Secure the panel with the two (2)
retaining screws. Close the front door and secure it with the latch.
7.
Switch ON AC power to the Load Center.
8.
After the Power Center is powered up the Wireless Controller will
automatically synchronize with the system and will be ready for
operation. Note: The initial connection can take up to 2-3
minutes.
9.
Proceed to the "Connecting the ScreenLogic Interface Indoor
Wireless Transceiver to the ScreenLogic Interface Protocol
Adapter" on page 8.
SCREENLOGIC
Control
Note: Multiple wires may be
inserted into a single screw COM
PORT terminal. However, this can
cause an intermittent connection.
Note: For additional COM ports,
an optional Serial COM Port
Expansion Board (P/N 520818)
can be installed in the low voltage
compartment.
®
INTERFACE Wireless Connection Kit Installation Guide