Bosch GWH 10-2 G Series Installation Manual And Operating Instructions page 19

Hide thumbs Also See for GWH 10-2 G Series:
Table of Contents

Advertisement

Problem
Digital display shows "EA".
Digital display shows "F0".
Digital display shows "F7".
Reduced water flow.
Table 7
6 720 608 992 (2021/02)
Cause
There is spark but the main burner does
not ignite, heater blocked.No ionisation
probe signal.
Power was activated with a hot water tap
running.
False Flame.
Insufficient water supply pressure.
Dirty taps or mixers.
Gas valve blocked.
Heat exchanger blocked (limescale).
Solution
Check:
Gas supply, position of valves, empty
LP gas cylinders.
Turn the water off and on. If the problem
persists, call a qualified technician.
Check for water tightness of flue.
Ensure no rain ingress.
Call a qualified technician.
Call a qualified technician.
Call a qualified technician
Call a qualified technician
Call a qualified technician
Problems
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh 13-2 g seriesGwh 16-2 g series

Table of Contents