prevents combustion gases from entering the room where the
gas heater has been installed. The probe restarts after a reset
period.
If the heater turns off during operation:
▶ Ventilate the room.
▶ After 10 minutes, turn on the heater once again.
Call a qualified technician if the same thing happens again.
DANGER:
The user must never touch the flue gas safety
device.
Service Checklist
Water valve
•
Diaphragm, replace if required
•
Water throttle, greased, O-rings replaced if required
•
Water filter, cleaned, replaced if required
•
Sleeve, greased, replaced if required
•
Water governor, clean
Gas valve
•
Pilot burner cleaned
•
Flame rod cleaned
•
Main burner, injectors and venturies cleaned
Hydrogenerator
•
Inlet clear of obstructions
Heat exchanger
•
Fins cleaned
•
Water connections checked and tightened
Gas pressure
•
Burner pressures checked and adjusted
•
Check inlet operating pressure
Flue
•
Check for obstructions and tightness
•
Negative pressure test
6 720 608 992 (2021/02)
Maintenance
17