Mounting, demounting and electric installation
Loss of degree of protection IP 66!
The housing in which the panel PC is installed, has to meet the
following conditions:
Free from impurities
Sufficient mechanical strength and flatness
These criteria influence the required IP degree of protection to a
great extent.
Further required measures have to be taken depending on the
mounting location, e. g. the stabilization of the mounting frame.
Material thickness to mount the Panel PC:
The panel PC is mounted into the housing. The material thickness of
the housing has to be between 2 and 6 mm.
1. Creating a mounting cut-out, refer to
page 38
2. Remove two mounting screws at the bottom of the display. These screws
fixedly attach the display when inserted into the mounting cut-out.
Fig. 10-16: Mounting screws at the bottom of the display
3. Install the panel PC into the mounting cut-out. The detents fasten the panel
PC in the opening.
Bosch Rexroth AG R911384699_Edition 03
IndraControl PR4 and VR4 Control cabi-
chapter 10.8 "Mounting cut-out" on
net PC and panel PC