Broan VENTILLATION FAN QTR100 Instructions Manual

Broan VENTILLATION FAN QTR100 Instructions Manual

Ventilation fan
Table of Contents

Advertisement

Available languages

Available languages

MODEL qtr100
VENtILAtION FAN
rEAD AND SAVE tHESE INStrUCtIONS
WArNING
tO rEDUCE tHE rISK OF FIrE, ELECtrIC SHOCK, Or IN-
JUrY tO PErSONS, OBSErVE tHE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUtION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
CLEANING & MAINtENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPErAtION
Use an on/off switch or speed control to operate this ventilator.
See "Connect Wiring" for details.
WArrANtY
BrOAN tHrEE YEAr LIMItED WArrANtY
Broan warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for
a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by Broan), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN'S OP-
TION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-
DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan at the address
or telephone number stated below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
MODEL qtr100
Page 

Advertisement

Table of Contents
loading

Summary of Contents for Broan VENTILLATION FAN QTR100

  • Page 1 To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence...
  • Page 2: Typical Installations

    tYPICAL INStALLAtIONS Housing mounted to I-joists. Use I-joist spacer block (provided). Housing mounted to joists. Housing mounted to truss. PLAN tHE INStALLAtION COOKING AREA Do not install above or inside this area. NOT FOR USE IN Cooking A COOKING AREA. Equipment ROOF CAP 4-IN. ROUND...
  • Page 3: Connect Wiring

    INStALL HOUSING & DUCt 1. Bend housing tabs. Use a pliers to bend housing tABS out to 90 2. Mount housing to (use for mounting to I-Joist) joist. Hold housing in place so that the housing tabs contact the bottom of the joist. The hous- ing mounts with four (4) screws or nails. Screw or nail housing to joist through lowest holes in each mount- ing flange, then through highest holes.
  • Page 4: Service Parts

    INStALL GrILLE 6. Finish ceiling. Install ceiling material. Cut out around housing. 7. Attach grille to housing. Squeeze grille springs and insert them into slots on each side of hous- ing. 8. Push grille against ceil- ing. SErVICE PArtS Key No. Part No. Description 97016466 Housing 97016449 Duct Connector-4” 98010102 Wiring Plate 99170245 Screw, #8-18 X .375 97016932 Wire Panel/Harness Assembly 99020284 Blower Wheel 99080582 Motor 99100491...
  • Page 5: Limpieza Y Mantenimiento

    IDAS (PERO SIN LIMITARSE A) GARANTÍAS IMPLÍCITAS DE COMER- CIALIZACIÓN O IDONEIDAD PARA UN PROPÓSITO PARTICULAR. Durante este período de tres años, Broan-NuTone, a su criterio, reparará o reemplazará, sin cargo algtreso, cualquier pieza o producto que se en- cuentre defectuoso bajo condiciones normales de uso y servicio.
  • Page 6: Instalaciones Típicas

    INStALACIONES tÍPICAS Montaje de cubierta en viguetas “I”. Utilice un taco separador de viguetas “I” (suminis- trado). Montaje de cubierta en viguetas. Montaje de cubierta en armadura. MODELO qtr100 PLANIFICACIÓN DE LA INStALACIÓN ÁREA QUE COCINA No instale sobre o dentro de esta área.
  • Page 7: Conexión Eléctrica

    INStALE LA CUBIErtA Y EL CONDUCtO 1. Doble las lengüetas de la cubi- erta. Con un alicate, doble las LENGÜE- tAS de la cubierta a 90 2. Monte la SEPARADOR (se usa para el montaje cubierta en a la vigueta “I”) la vigueta. Sostenga la cubi- erta en su lugar de manera que las lengüetas de la cubierta hagan con- tacto con la parte inferior de la vigu- eta.
  • Page 8: Piezas De Repuesto

    INStALE LA rEJILLA 6. termine el cielo raso. Instale el material del cielo raso. Recorte alrededor de la cubierta. 7. Acople la rejilla a la cubierta. Apriete los resortes de la rejilla e insér- telos en las ranuras que se encuentran a cada lado de la cubierta. 8. Empuje la rejilla contra el cielo raso. PIEZAS DE rEPUEStO Clave n. Pieza n. Descripción 97016466 Cubierta 97016449...

This manual is also suitable for:

Qtr100

Table of Contents